PROTON 206/308 V1 System Manual
25
Step 3
Use following command to enable/disable CDC for incoming calls:
3333-Station-Day Time-Night Time
Where,
Station is from 21 to 28.
Use following command to enable/disable CDC for incoming calls for all stations:
3333-*-Day Time-Night Time
By default, CDC for incoming calls is disabled during day time and night time.
Step 4
Use following command to enable/disable CDC warning beeps without disconnection:
3334-Station-Day Time-Night Time
Where,
Station is from 21 to 28.
Use following command to enable/disable CDC warning beeps without disconnection:
3334-*-Day Time-Night Time
By default, CDC warning beeps are enabled during day time and night time.
Step 5
Timers of Relevance:
Disconnection time should be programmed for different call types using following table:
Examples:
Program CDC for incoming calls on station 23 during daytime for 4 minutes. The system should give me beep
after 3.5 minutes.
Use following commands:
3333-23-1-0
217-28-210
217-29-30
Program CDC for STD calls on station 21 during nighttime for 5 minutes. The system should give me beep after
4 minutes.
Use following commands:
3332-21-0-1
217-27-240
217-29-60
Day Time
Night Time
Meaning
0
0
CDC is disabled
1
1
CDC is enabled
Day Time
Night Time
Meaning
0
0
CDC is disabled
1
1
CDC is enabled
Command
Description
Range
Default
Unit
217-26-Timer
CDC local warn timer
001-255
240
Sec
217-27-Timer
CDC STD warn timer
001-255
120
Sec
217-28-Timer
CDC incoming warn timer
001-255
240
Sec
217-29-Timer
CDC good-bye timer
01-99
60
Sec
Содержание Proton 206
Страница 1: ...PROTON 206 308 System Manual ...
Страница 2: ......
Страница 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Страница 8: ...8 PROTON 206 308 V1 System Manual ...
Страница 86: ...86 PROTON 206 308 V1 System Manual ...
Страница 92: ...92 PROTON 206 308 V1 System Manual ...
Страница 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...
Страница 97: ...PROTON 206 308 V1 System Manual 97 ...