background image

MSC-XDM2000S Product Manual

2.6 Command Tab

Figure 14: Command Tab

The Command Tab (Figure 14) provides access to the Mascot protocol interface.  Commands are typed on the 
Command text entry line followed by pressing the Enter key to execute them.  The results will be displayed in 
the text area below the command line.  Clicking the 

Clear Output

 button will clear all command output in the 

lower area.

See the section 

Mascot Control Protocol

 for more information.

Page 22 of 64

© 2013-2018 Matrix Switch Corporation

www.matrixswitch

 

 corp.com

 

 

Содержание MSC-XDM2000S

Страница 1: ...x Switch Corporation MSC XDM2000S Product Manual 1RU 32 input 32 output 3G SDI Modular Video Router with Status Panel Revision 1 8 Page 1 of 64 2013 2018 Matrix Switch Corporation www matrixswitchcorp...

Страница 2: ...ALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corporation devices in life su...

Страница 3: ...commands and Panel GPIO commands Improved Software Update documentation Added pinouts for RS 232 and RS 485 serial port and GPIO Auxiliary interface Added XD series systems Revision 1 3 2016 05 17 Ad...

Страница 4: ...nnection 17 2 2 2 Loading a preset 17 2 3 Presets Tab 17 2 3 1 Loading Work Matrix from a source target 18 2 3 2 Saving Work Matrix to a target 18 2 3 3 Usage scenarios 18 2 4 Labels Tab 18 2 5 Config...

Страница 5: ...mand 41 3 11 21 PAdd Command 41 3 11 22 PairIO Command 41 3 11 23 PanelCmd Command 42 3 11 24 PanelCmdEn Command 43 3 11 25 PanelCond Command 43 3 11 26 PanelDis Command 44 3 11 27 PanelExtEn Command...

Страница 6: ...very procedure 56 4 3 TFTP Software 57 4 3 1 Windows 57 4 3 2 Mac OS X 58 4 3 3 Linux 58 5 Troubleshooting 60 5 1 Unknown IP address 60 5 2 Unexpected reboots 60 6 Reference 61 6 1 Specifications 61 6...

Страница 7: ...cted Inputs with supported standard rate 3G HD or SD SDI signals will be auto re clocked for reduced jitter Other non standard rates between 125 Mbit s and 3 0 Gbit s will be passed through without re...

Страница 8: ...tails General Purpose I O A D25 connector provides a GPIO auxiliary port with up to 24 input or output 3 3V logic lines for control and status interfacing with external equipment LEDs buttons etc See...

Страница 9: ...r by feel slightly more difficult 3 Ensuring the correct type of board is being used for a slot Input or Output position the board connector first opposite side of the BNC connectors and board main co...

Страница 10: ...it is inserted into To remain cost effective it is thus recommended that transmit only or receive only SFP modules are used when planning system I O Model Description MSC SFPTX F1310 10KM 3G SDI SFP V...

Страница 11: ...the Software failsafe recovery procedure is entered Routing matrix is initialized to Preset 0 state defaults to source 1 connected to all destinations 1 4 Front Status Panel The MSC XDM2000S has a st...

Страница 12: ...udio Routers 192 168 2 60 Remote Button Panels 192 168 2 64 Remote LCD Screen Panels 192 168 2 80 Table 4 Default System IP Addresses To access the web page interface of the device 1 Connect the Ether...

Страница 13: ...Web Page Interface can be used for modifying labels Click the Save button to store any changes that are made Refer the Labels Tab section for more details 1 5 5 Presets There are 10 stored matrix rout...

Страница 14: ...etwork unique IP addresses should be assigned from the applicable network and the Netmask setting of the devices should be set to reflect the class size of the IP network the default of 255 255 255 0...

Страница 15: ...nstallation example consisting of a 32x32 SDI Video Router with a secondary level 32x32 Analog Audio router connected via the AFV DB 25 interface a 32x32 Remote Button Panel a 2RU LCD Remote Panel and...

Страница 16: ...tlines to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 10 1 S...

Страница 17: ...e Destination or a single level is selected 2 2 2 Loading a preset Presets store connection states for one or more Destinations Loading a Preset on the Routing tab consists of simply clicking on the L...

Страница 18: ...o a Preset will store the Work Matrix state to non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets T...

Страница 19: ...lumns for Video and Audio Sources and Destinations Single level routers will have a column for Source labels and one for Destination labels On multi level routers secondary levels can be left blank to...

Страница 20: ...characters displayed at the top of the Web Page interface which is helpful when managing multiple systems Disable Reclockers Disable SDI reclockers not supported by all Routers 3D I O Pairing Enable...

Страница 21: ...e panels control different levels of a Video Audio Router Control Mode Set the matrix control mode only present on Routers Available options include Local Button panel controls the router itself Remot...

Страница 22: ...he Command text entry line followed by pressing the Enter key to execute them The results will be displayed in the text area below the command line Clicking the Clear Output button will clear all comm...

Страница 23: ...without modification using this protocol For information about other third party control system manufacturers who support MASCOT contact Matrix Switch Corporation 3 1 Protocol Changes As new commands...

Страница 24: ...nd prompt character 3 3 Serial Access Matrix Switch router systems come equipped with a serial port which can be used as another means of sending Mascot commands Connect a Computer system to the devic...

Страница 25: ...SCII 10 The Prompt A prompt character is displayed each time a command or chain of commands is entered to indicate readiness to receive additional commands If an error occurs in response to a command...

Страница 26: ...matically interpret argument as string spaces and commas not allowed Hex 0x3D 0xNN where NN are 2 hex digits from 0 9 A F or a f Double quoted One or more characters surrounded by double quotes An Arg...

Страница 27: ...orted String String A generic string argument max length depends on the command Value A general value Value type depends on setting See System Parameters Table 8 Command Argument Types 3 7 System Para...

Страница 28: ...erial port baud rate in bits second ctl serial2 log Boolean RW AS RS 485 serial port protocol log enable ctl serial2 proto String RW AS RS 485 serial port protocol selection mascot svs etc mtx serial...

Страница 29: ...implementation and support variations between different system types Many of these commands have been superseded by System Parameters in Mascot protocol version 3 0 Command Arguments Description DHCP...

Страница 30: ...ail Please note that command availability may vary between firmware series and versions Details of availability are documented for each command 3 11 1 C Command Routers and MSC GCP2U32 only NOTE Super...

Страница 31: ...assigned via the IP Netmask and Gateway commands A value of 1 enables DHCP and will obtain the values for the IP address Netmask and Gateway from your DHCP server This value is saved and recalled on...

Страница 32: ...echo enable E 0 1 Set matrix echo enable 0 to disable 1 to enable Examples to query and then enable matrix echo E 0 E 1 3 11 5 Firmware Command NOTE Superseded by the sys firmware System Parameter Que...

Страница 33: ...meter Table for a list of currently defined parameters This command supersedes many individual configuration commands NOTE This command queries Active values of parameters which may differ from values...

Страница 34: ...arameter identifier separated by an equals character and the value GetS Parameter Display the Stored value of a single parameter or a subset of parameters under a given parameter node 3 11 10 Help Com...

Страница 35: ...etection for outputs Format is one decimal number per output 0 Unlocked 1 SD 2 HD Example for a 16x4 system SD HD Unlocked Unlocked LockStatus 1 2 0 0 3 11 13 MAC Command NOTE Superseded by the net ma...

Страница 36: ...ination 2 on the second level The second example queries the mapping for a single destination The third example maps destination 1 to physical destination 5 on all levels The fourth example maps desti...

Страница 37: ...over what protocol version is in use The returned value is either an integer such as 2 or major and minor version numbers separated by a period such as 2 3 Example MascotVer 2 3 3 11 17 MtxCfg Command...

Страница 38: ...or reclocker disable If an argument is specified 0 7 then a more descriptive JSON structure is returned of the following form newlines and spaces added as a visual aid but are not necessarily part of...

Страница 39: ...to response as a visual aid MtxCfg7 version 1 status OK levels name Level1 type VIDEO destCount 4 srcCount 4 flags mute destNames Dest1 Dest2 Dest3 Dest4 srcNames Src1 Src2 Src3 Src4 state 1 2 3 4 ps...

Страница 40: ...assigning I O grouping MtxGroup 1 1 MtxGroup 2 4 MtxGroup 2 4 The first example MtxGroup command shows that I O grouping is disabled on both levels of a 2 level system The second command configures th...

Страница 41: ...preset information which is retained and available through system power cycles Command Description PAdd PRESET DEST SRC Add a connection of SRC to DEST on PRESET for all levels PAdd PRESET DEST SRC LE...

Страница 42: ...nel buttons and GPIO pins are specified by numeric ID Panel buttons are numbered beginning with ID number 1 Panel button order depends on the panel but generally has the top left button as button 1 fo...

Страница 43: ...1 Enable or disable panel button GPIO command and conditions 0 disable 1 enable Examples for querying and enabling panel command conditions PanelCmdEn 0 PanelCmdEn 1 3 11 25 PanelCond Command Protocol...

Страница 44: ...Examples PanelCond 1 P0 2 P1 67 P0 PanelCond 1 1 P0 PanelCond 68 P1 PanelCond 68 The first example above queries the currently assigned panel GPIO conditions which shows that button number 1 and 2 ha...

Страница 45: ...PanelExtEn 1 The first command queries the current external panel interface setting 0 disabled The second command enables the external panel interface 3 11 28 PanelRate Command Protocol Version 2 1 Fo...

Страница 46: ...l serial2 proto System Parameters Query or assign the serial protocol The only available option is currently the case insensitive value Mascot however additional control protocols may be added in the...

Страница 47: ...command changes preset data which is stored and persists through power cycles Command Description PSub PRESET DEST Remove any existing connection to DEST in PRESET for any level PSub PRESET DEST LEVE...

Страница 48: ...3 11 34 Reboot Command Instructs the system to reboot which is done after a brief delay Ensures that all outstanding data writes are written to non volatile memory prior to the reboot 3 11 35 ReclkDis...

Страница 49: ...he final command sets the IP address of the router to sync secondary router 3 11 37 S Command Routers and MSC GCP2U32 only Query the current matrix routing state Source values for all levels of every...

Страница 50: ...nd or Stored parameter values Behavior depends on the parameter and is defined in the System Parameter Table Values in Stored memory are loaded at system startup See System Parameters for more details...

Страница 51: ...system parameter Stored values only Values set with this command will not take effect until the system is restarted NOTE Some parameters may not be assignable in Stored memory for example if it does n...

Страница 52: ...t level label should be used 3 11 43 SysName Command NOTE Superseded by the sys name System Parameter Query or assign system name The system name is provided for convenience when managing multiple Mat...

Страница 53: ...system with older firmware not supporting the SysType command the second example is what might be returned by an MSC GCP2U32 LCD panel 3 11 45 Vars Command Protocol Version 2 3 Display all system conf...

Страница 54: ...PRESET Write current matrix routing state to PRESET Example to save state to preset 1 W 1 3 11 47 WebPass Command Assign a web password to password protect the web page interface The serial and TCP I...

Страница 55: ...can be used for SRC to Mute a destination if supported for a given level Examples X 1 1 2 2 3 8 0 4 X 3 3 8 X 3 4 X 4 0 2 In the above examples the first command queries the matrix routing state typic...

Страница 56: ...image has been transferred to the device s FLASH storage area 5 The device will automatically reboot to perform the remainder of the software update during which the web page interface may display a...

Страница 57: ...to the IP address 192 168 2 59 Consult the TFTP Software section for details 4 3 TFTP Software There are many different options for TFTP client programs the choice of which depends on what operating s...

Страница 58: ...put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initiate the TFTP transfer...

Страница 59: ...TFTP transfer binary put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initi...

Страница 60: ...running A computer system can then be configured with an IP address on the same IP subnet and the webpage configuration can be loaded for viewing and changing the IP address as described in the sectio...

Страница 61: ...g C Operating Temp 0 Through 75 Deg C Humidity 0 Through 90 Non Condensing Warranty 2 Years Parts Labor SDI Video Connector type BNC Data Types SMPTE 259M 292M 424M Data Rates 19 Mbit s through 3 0 Gb...

Страница 62: ...more RS 485 connected devices Pin Name Function 1 4 6 7 NC Not Connected 2 TX RS 232 Transmit 3 RX RS 232 Receive 8 D RS 485 Data Positive 9 D RS 485 Data Negative 5 GND Ground DE 9 Pin Numbers 6 3 GP...

Страница 63: ...means it is silenced Output Synonymous with Destination Preset Matrix Switch Corporation Router devices provide 10 presets which store matrix Routing connections When a preset is recalled zero or more...

Страница 64: ...which shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or modification EXCEPT AS SET FORTH...