MSC-CP16X4E Product Manual
command. This setting is stored and recalled on power up.
Command
Description
PanelOfs
Query current panel offset settings, 4 values are returned
separated by commas, corresponding to the same values which
are assigned.
PanelOfs DESTOFS, SRCOFS, LVL1, LVL2
Assign panel destination/source offsets and level control
values.
The DESTOFS parameter assigns a destination offset that determines which destination the button panel starts
on, 0 is used for no offset (default). The SRCOFS parameter is used likewise to assign a source offset. The
LVL1 and LVL2 parameters are used for modifying what levels the panel will control. The default is 0 for both
values which uses the default levels of 1 and 2 for the primary and secondary levels respectively. If LVL1 is
assigned a value other than 0 and LVL2 is 0 then the secondary level control will be disabled.
Examples
>PanelOfs
0,0,0,0
>PanelOfs 1,0,0,0
>PanelOfs 0,0,2,0
>
The first command just queries the current panel offset values, which returns all 0s (the default). The second
command assigns 1,0,0,0 which sets a destination offset of 1, which will set the first destination of the button
panel to destination 2. The third command sets up a button panel to control the 2nd level of a router.
3.29 PanelDis Command
Carina series only - Protocol Version: 2.4
Query or assign internal button interface panel disable setting. This setting is stored and recalled on power up.
Command
Description
PanelDis
Query internal panel disable setting.
PanelDis 0 | 1
Assign internal panel disable setting (0: enable, 1: disable)
Examples
>PanelDis
0
>PanelDis 1
>
The first command queries the current panel disable setting (0: enabled). The second command disables the
internal panel interface.
Page 30 of 48
Copyright © 2013-2015 Matrix Switch Corporation