Description
This command will load the wide vertical bar characters into the volitile
memory. If you have stored your own custom vertical bar data, use the
’Load Custom Characters’ command instead to load your custom bar
data into the volitile memory. This command will allow you to use the
’Place Vertical Bar’ command.
NOTE
Wide bars have a width of five pixels.
Remembered
No
6.12 Place Verticle Bar
Syntax
Hexadecimal
0xFE 0x3D [Column] [Length]
Decimal
254 61 [Column] [Length]
ASCII
254 “=” [Column] [Length]
Parameters
Parameter
Length
Description
Column
1
The column number.
Length
1
The length of the bar data.
Description
This command will place a bar graph at the specified [Column] with the
specified [Length]. The [Length] is the size in pixels of the bar graph,
each row of the is seven pixels tall, so to specify a length of two and a
half rows use a length value of seventeen.
Remembered
No
7 General Purpose Output
7.1 Introduction
General purpose outputs allow you to connect devices, such as temperature probes, to the and supply
them with up to 30mA of current at 5V. The has 6 GPOs which are software controlled, with functions to
turn them on/off and set the power state for the next startup.
Matrix Orbital
PK202-25
31
Содержание PK202-25
Страница 1: ...PK202 25 Technical Manual Revision 4 0 ...
Страница 6: ...Figure 2 12V Power Cable Adapter V VPT Models Figure 3 Breadboard Cable Matrix Orbital PK202 25 2 ...
Страница 7: ...Figure 4 Serial Cable 4FT Figure 5 Communication and 5V Power Cable Matrix Orbital PK202 25 3 ...
Страница 8: ...Figure 6 Aluminum Mountings Figure 7 Keypad Mountings Matrix Orbital PK202 25 4 ...
Страница 9: ...Figure 8 Mounting Kits Figure 9 4X4 Keypad Matrix Orbital PK202 25 5 ...
Страница 59: ...14 3 Physical Layout Figure 21 Physical Diagram Matrix Orbital PK202 25 55 ...