![Matrix Orbital LK204-25-USB Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/matrix-orbital/lk204-25-usb/lk204-25-usb_technical-manual_1741147036.webp)
7.2
General Purpose Output Off
Syntax
Hexadecimal
0xFE 0x56 [Num]
Decimal
254 86 [Num]
ASCII
254 “V” [Num]
Parameters
Parameter
Length
Description
Num
1
GPO number.
Description
This command turns OFF general purpose output [num].
NOTE
OFF means that the output is pulled LOW.
Remembered
Yes
7.3
General Purpose Output On
Syntax
Hexadecimal
0xFE 0x57 [Num]
Decimal
254 87 [Num]
ASCII
254 “W” [Num]
Parameters
Parameter
Length
Description
Num
1
GPO number.
Description
This command turns ON general purpose output [num]. The standard
GPO’s on the LK204-25-USB output 20mA of current at 5V.
NOTE
ON means the output is pulled HIGH.
Remembered
Yes
7.4
Set Startup GPO state
Syntax
Hexadecimal
0xFE 0xC3 [Num] [state]
Decimal
254 195 [Num] [state]
Parameters
Parameter
Length
Description
Num
1
GPO number.
state
1
Startup state (0: Off, 1: On)