Description
This command will place a bar graph at the specified [Column] with the
specified [Length]. The [Length] is the size in pixels of the bar graph.
NOTES
•
A Vertical Bar style must be initialized before this command is executed.
•
Bar graphs may be one directional only.
Remembered
No
7
General Purpose Output
7.1
Introduction
General purpose outputs allow you to connect devices, such as LEDs, to the LK202-25 and supply them
with up to 20mA of current at 5V. The LK202-25 has 6 GPOs which are software controlled, with functions
to turn them on/off and set the power state for the next startup.
7.2
General Purpose Output Off
Syntax
Hexadecimal
0xFE 0x56 [Num]
Decimal
254 86 [Num]
ASCII
254 “V” [Num]
Parameters
Parameter
Length
Description
Num
1
GPO number.
Description
This command turns OFF general purpose output [num].
NOTE
OFF means that the output is pulled LOW.
Remembered
Yes
7.3
General Purpose Output On
Syntax
Hexadecimal
0xFE 0x57 [Num]
Decimal
254 87 [Num]
ASCII
254 “W” [Num]
Parameters
Parameter
Length
Description
Num
1
GPO number.
Matrix Orbital
LK202-25
33
electronic components distributor