Table 9: Example of an ASCII Table
Letter/ Number
Decimal Value
Hex Value
A
65
41
a
97
61
0
48
30
9
57
39
This gives rise to the possibility of confusion when parameters are being set on the display. For example,
the GPO ON and OFF commands use a number to indicate which GPO is being controlled. We’re told that
acceptable values are 0 to 8. All such parameters must use numeric values (i.e., the actual byte values). If
we send the ASCII number 0 by mistake it will actually give the value 48 decimal (30 hex) to the parameter,
which is wrong.
In the tables given in the following sections ASCII characters are shown as ’A’, with single quotes.
6.4 Text Commands
Syntax in the tables below is given in hex, decimal and decimal with ASCII, in that order, one per line.
Table 10: Text Commands
Command
Syntax
Default
Notes
Auto line wrap on
FE 43
254 67
254’C’
off
Enables
line
wrapping
(not
word wrap).
Auto line wrap off
FE 44
254 68
254 ’D’
off
Disables
line
wrapping.
Auto scroll on
FE 51
254 81
254 ’Q’
off
Enables scroll at
bottom of screen.
Text will push
display up one
line to make room
for new line.
Auto scroll off
FE 52
254 82
254 ’R’
off
Disables
auto
scroll. Text will
wrap to top left
and
overwrite
existing text.
Matrix Orbital
LCD2041
22
Содержание LCD2041
Страница 1: ...LCD2041 Technical Manual Revision 2 0 ...
Страница 30: ...Figure 20 Physical Layout Matrix Orbital LCD2041 27 ...