background image

Technical Manual 

Wireless CAN Bridge 500  (CB-500LR) 

 

Matric Technical Manual 185-0054, V1 

 

Page 2 of 12 

 

 

 
 
SPECIFICATIONS: 
 
Functional 

1200 frames per second transfer rate (max) 
Supports any CAN Bus or DeviceNet* (Bosch CAN 2.0b) 
Network baud rate (125K, 250K, 500K) 
Five pin male micro connector 
16 bit CPU 
CPU watchdog 

 
Radio 

Typical range of 1400 feet with unobstructed line of sight 
2.4 – 2.4835 GHz with 15 channels 
FSK modulation 
Output power, 3.5 mW 
Single heterodyne conversion 
Radio complies with FCC Part 15B, no user license required 

 
Configuration Options 

Configuration via internal dip switches 
Radio link master or slave 
Standard versus extended CAN frame formats 
Frequency agile enable / disable 
Channel (1-15) 
Radio retry level 

 
Power Source 

Requires SELV power supply at connector “Network”. 
See installation section for wiring information. 
7-30VDC, 200 mA at 24VDC +/- 5% 

 
Status Indicators 

Signal strength 
Bus loading 
Data Loss Cause 
Power  

 
Physical 

Size: 3 1/8 X 3 X 6 5/16 Inches 
Weight: 1 Lb 
DIN rail or panel mount 
Sealed enclosure  
Operational temperature 0°C to 70°C 
Storage temperature -40ºC to 85ºC 

 

Содержание CB-500LR

Страница 1: ...ireless link can communicate at a separation of up to 1400 feet A full 64 node DeviceNet can be implemented depending on scan rates and frame density Since actual CAN messages are transferred the Wire...

Страница 2: ...heterodyne conversion Radio complies with FCC Part 15B no user license required Configuration Options Configuration via internal dip switches Radio link master or slave Standard versus extended CAN f...

Страница 3: ...eet separation without significant RF obstacles The actual transfer rate in any application is dependent upon the quality of the RF link Structural components such as steel walls or decking earth tunn...

Страница 4: ...validate agency approvals To access configuration switches first use a flat screwdriver to pry off the two decorative covers at the right and left ends of the lid Four pry slots are provided as shown...

Страница 5: ...radios A Radio System must consist of only one Server master and only one Client slave per channel The Server is the initiator of the radio pair Before the radios link the Client will only listen for...

Страница 6: ...nt exceeded Note Both units must have this enabled for the feature to work properly Switches S2 5 6 Selects the number of retries The radio will retransmit an unsuccessful packet the selected number o...

Страница 7: ...xhausted Scanner retries must be set at a level that mitigates data loss at the system level Strong Indicates the best data throughput Data packets are being transferred to the radio at a rate equival...

Страница 8: ...CAN packets Power Indicator The power indicator implies the presence of electrical power It is a hardwired LED that does not indicate the quality of the power detected Heavy 50 100 of the available ba...

Страница 9: ...nce Suggested specifications are listed below Panel Fastener 1 2 inch plywood 5 8 x 8 wood screw 1 8 inch aluminum 10 32 machine screw to threaded hole or bolt 1 2 inch plaster board Wall anchor with...

Страница 10: ...equires a SELV power supply with power output intrinsically limited to under 8 amps at a maximum of 30VDC If a protective device is used with a power supply that exceeds this requirement it must be ra...

Страница 11: ...n Consult Safety Code 6 obtainable from Health Canada s website at www hc sc gc ca rpb These simple precautions must be taken to prevent general population and installation personnel from exposure to...

Страница 12: ...ess CAN Bridge 500 CB 500LR Matric Technical Manual 185 0054 V1 Page 12 of 12 For technical support contact Matric 2099 Hill City Road Seneca PA 16346 814 677 0716 www matric com DeviceNet is a regist...