background image

Technical Manual 

Wireless CAN Bridge 500  (CB-500LR) 

 

Matric Technical Manual 185-0054, V1 

 

Page 10 of 12 

 

1

5

4

3

2

6

 

 

The Wireless CAN Bridge provides a sealed micro style connector (labeled “Network”) 
that complies with the physical standards for DeviceNet* connectors.  The CB-500LR 
requires a tap to interface into the DeviceNet* trunk line.  The pinout for the connector is 
shown below.  Note: The CAN Bridge 500 requires a SELV power supply with power 
output intrinsically limited to under 8 amps at a maximum of 30VDC.  If a protective 
device is used with a power supply that exceeds this requirement it must be rated to trip 
at a current equal to 1000/Vin. Protective devices must be fuses or breakers and must 
be non-adjustable, nonautoreset, electromechanical devices. 

 

 

 
 
 

Network 
Male (pins) 
 
1 – Drain (bare) 
2 – V+ (red) 
3 – V- (black) 
4 – CAN_H (white) 
5 – CAN_L (blue) 

 
 
 
 
The Wireless CAN Bridge provides factory test functions via a sealed micro style 
connector (labeled “Auxiliary”).  This connector is not used during normal operation. 

 
 

 

1

2

4

3

5

Содержание CB-500LR

Страница 1: ...ireless link can communicate at a separation of up to 1400 feet A full 64 node DeviceNet can be implemented depending on scan rates and frame density Since actual CAN messages are transferred the Wire...

Страница 2: ...heterodyne conversion Radio complies with FCC Part 15B no user license required Configuration Options Configuration via internal dip switches Radio link master or slave Standard versus extended CAN f...

Страница 3: ...eet separation without significant RF obstacles The actual transfer rate in any application is dependent upon the quality of the RF link Structural components such as steel walls or decking earth tunn...

Страница 4: ...validate agency approvals To access configuration switches first use a flat screwdriver to pry off the two decorative covers at the right and left ends of the lid Four pry slots are provided as shown...

Страница 5: ...radios A Radio System must consist of only one Server master and only one Client slave per channel The Server is the initiator of the radio pair Before the radios link the Client will only listen for...

Страница 6: ...nt exceeded Note Both units must have this enabled for the feature to work properly Switches S2 5 6 Selects the number of retries The radio will retransmit an unsuccessful packet the selected number o...

Страница 7: ...xhausted Scanner retries must be set at a level that mitigates data loss at the system level Strong Indicates the best data throughput Data packets are being transferred to the radio at a rate equival...

Страница 8: ...CAN packets Power Indicator The power indicator implies the presence of electrical power It is a hardwired LED that does not indicate the quality of the power detected Heavy 50 100 of the available ba...

Страница 9: ...nce Suggested specifications are listed below Panel Fastener 1 2 inch plywood 5 8 x 8 wood screw 1 8 inch aluminum 10 32 machine screw to threaded hole or bolt 1 2 inch plaster board Wall anchor with...

Страница 10: ...equires a SELV power supply with power output intrinsically limited to under 8 amps at a maximum of 30VDC If a protective device is used with a power supply that exceeds this requirement it must be ra...

Страница 11: ...n Consult Safety Code 6 obtainable from Health Canada s website at www hc sc gc ca rpb These simple precautions must be taken to prevent general population and installation personnel from exposure to...

Страница 12: ...ess CAN Bridge 500 CB 500LR Matric Technical Manual 185 0054 V1 Page 12 of 12 For technical support contact Matric 2099 Hill City Road Seneca PA 16346 814 677 0716 www matric com DeviceNet is a regist...

Отзывы: