ETC Report No. : 16-09-RBF-027
Sheet 4
of 36 Sheets
FCC ID:
2AC96WDP
4
For intentional radiator device, per §15.249(a), the field strength of emissions shall
comply with the following :
Frequency
MHz
Distance
Meters
Fundamental
dBμV/m
mV/m
Harmonic
dBμV/m
μV/m
902 - 928
3
94
50
54
500
2400 - 2483.5
3
94
50
54
500
5725 - 5875
3
94
50
54
500
24000 - 24250
3
108
250
68
2500
In accordance with §15.249(e), limits shown in above table are based on average limits
for frequencies above 1000 MHz, and frequencies below 1000 MHz are based on quasi
peak. However, the peak field strength of any emission shall not exceed the maximum
permitted average limits by more than 20 dB.
(3) Spurious in Out Band Requirement
For intentional device, according to §15.249 (d), emissions radiated outside of the
specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB
below the level of fundamental or to the general radiated emission limits in §15.209.
(4) Antenna Requirement
For intentional device, according to §15.203, an intentional radiator shall be designed to
ensure that no antenna other than that furnished by the responsible party shall be used
with the device.