Air Compressor
Specifications
Sprinter User's Manual
4-3
Air Compressor
Air Compressor
5.5 Bar
Air supply flow rate
50 ltr/min
We recommend you to install an air dryer in addition to the air compressor and
locate it between the compressor and the printer.
We also recommend you to connect the air compressor and the air dryer to
separate phases from the printer.
Temperature Control System (TCS)
Cooling Capacity
16,000 BTU/Hr minimum for SprinterB 36”
20,000 BTU/Hr minimum for SprinterB 40”
Liquid Outlet Temp
15
°
C
Liquid
Motor cooling liquid (anti-freeze) – recommended, or water.
Flow Rate
5–10 GPM
LCS location
Indoor, 3–5m from the printer
Connection
Requirements
Inlet: flexible tube – 8mm outside dia, 6mm inside dia.
Outlet flexible tube – 8mm outside dia, 6mm inside dia.
We recommend that you consult with your local chiller provider for the above
requirements. Further information is available for example, at
http://www.liquidchillers.com.
Pneumatics
Air supply pressure
4 Bar (36”) 4.5 Bar (40”)
Air supply flow rate
50 ltr/min
Operating Conditions
Temperature
20
°
c-28
°
c (Room temperature)
Humidity
40% to 70% (Room humidity)
Содержание The SprinterB
Страница 1: ...The SprinterB User s Manual...
Страница 4: ......
Страница 14: ...x The SprinterB User s M Figure 12 18 The PhotoPRINT Server Properties Window 12 12...
Страница 18: ...Important Notes Getting Started 1 4 Sprinter User s Manual This page has been intentionally left blank...
Страница 20: ...Overview 2 2 Sprinter User s Manual This page has been intentionally been left blank...
Страница 132: ...Ten Rules for Printing Files 12 2 Sprinter User s Manual This page has been intentionally left blank...
Страница 152: ...Troubleshooting IV Sprinter User s Manual Adjusting the Substrate Brakes Torque...