Troubleshooting_____________________________________________________________________________________ 

Problems 

Possible Causes 

Pump dose not   

run and hums 

* Line circuit breaker is off, or fuse is burned or loosed.

 

* Water level in sump has not reached turn-on level as indicated 

in installation drawing on the carton.   

* Pump cord is not making contact in receptacle.

 

* Float (optional) is stuck. It should operate freely in basin.

 

* If all of the above are OK and then the motor could be operate.

 

Pump runs 

but does not 

deliver water 

 

* Check valve (optional) is installed backwards. (Not included with pump) 
  Arrow on valve should point in direction of flow. 
* Discharge shut-off valve (if used) may be closed.

 

* Impeller or volute openings are fully or partially clogged. 

Remove pump and clean.

 

* Pump is air-locked. Start and stop several times by plugging and 

unplugging cord. Check for clogged vent hole in pump case.

 

* Inlet holes in pump base are clogged. Remove pump and clean the openings.

 

*  Vertical  pumping  distance  is  too  high  or  the  pipe  size  is  too  small.  Reduce 
vertical distance or increase the pipe size fittings.

 

Pump runs and 

Pump out sump, 

but does not stop. 

* Float (optional) is stuck in up position. Be sure float operates freely in basin.

 

* Defective float switch. Replace with float switch.

 

* Defective vertical switch. Replace with vertical switch.

 

Pump runs but 

delivers only a small 

amount of water 

* Pump is air-locked. Start and stop several times by plugging and unplugging 
  cord. Check for clogged vent hole in pump case. 
* Vertical pumping distance is too high or pipe size is too small. Reduce vertical 
distance or increase the pipe size. 
*Inlet holes in pump base are clogged. 
Remove pump and clean the openings. 
* Impeller or volute openings are fully or partially clogged. 
Remove pump and clean. 
* Pump impeller is partially clogged with debris, tar or paint, causing motor 
  to run slow and overload. Remove pump and clean. 

Fuse blows or circuit 

breaker trips when 

pump starts. 

* Pump impeller is partially clogged with debris, tar or paint, causing motor 
to run slow and overload. Remove pump and clean. 
* Motor stator may be defective. 
* Fuse size or circuit breaker may be too small. (Must be 15 amps). 
* Impeller or volute opening are fully or partially clogged. 
  Remove pump and clean. 

Motor runs for a 

short time, then 

stops. 

* Inlet holes in pump base are clogged. Remove pump and clean the openings. 
* Pump impeller is partially clogged with debris, tar or paint, causing motor 
  to run slow and overload. Remove pump and clean. 
* Motor stator may be defective. 
* Impeller or volute openings are fully or partially clogged. 
  Remove pump and clean. 

 

 

 

 

 

 

 

Matala 
 

Make water alive

” 

 

®

 

Содержание GM-3900

Страница 1: ...ax Flow Series Waterfall Pump This instruction manual explains the product operations and gives important precautions regarding its safe use In order to use the product to maximum benefit be sure to read the instructions thoroughly and follow them carefully To avoid accident do not use the pump in any way other than as described in this instruction manual especially when you see WARNING After read...

Страница 2: ...IL C60 1 19 O RING NBR 1 5 LOWER BEARING COVER FC200 1 20 PACKING NBR 1 6 OIL SEAL COVER NYLON 30 GF 1 21 SCREW SUS304 1 NYLON 30 GF for 22 STRAINER NYLON 30 GF 1 GM3900 GM4700 23 PUMP FEET SHEATH NBR 1 SUS430 PU for 24 WASHER SUS304 1 GM5400 GM6200 25 WASHER SUS304 1 8 UPPER PUMP CASING NYLON 30 GF 1 26 NUT SUS304 1 9 LOWER PUMP CASING PP 30 GF 1 27 KEY SUS304 1 10 CAPACITOR 1 28 SCREW SUS304 8 1...

Страница 3: ...se of your pump Other specifications are noted in the chart below Dimension Weight Hp W Inch mm Head Ft M Flow GPH LPH Head Ft M Flow GPH LPH L x W x H Inch mm lb kg GM 3900 1 5 150 1 1 2 38 11 5 2026GPH 22 5 3900GPH 9 4x6 5x14 240 165 355mm 15 4 7 GM 4700 1 3 250 2 50 13 3480GPH 27 5 4700GPH 9 4x6 5x14 240 165 355mm 15 4 7 GM 5400 1 2 400 2 50 16 3600GPH 32 8 5400GPH 9 4x6 5x14 8 240 165 375mm 17...

Страница 4: ...equipment out of the reach of children Warns that the failure to follow the directions given could cause serious risk to individuals or objects WARING This sign warns the operator that the failure to follow an instruction may damage the pump and or the system WARNING ...

Страница 5: ...o not connect pump to a power supply until permanently grounded For maximum safety connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the pump s grounding wire 5 Voltage of power supply must match the voltage of the pump 6 Before installing pump clear sump basin of any water debris or sediment WARNING Sump basin must be vented in accordance with loc...

Страница 6: ...curred by any customer in removing and or reaffixing any Matala Pump product parts or component THE WARRANTY WILL NOT APPLY a to defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and the parts used in connection wi...

Страница 7: ...reely in basin Defective float switch Replace with float switch Defective vertical switch Replace with vertical switch Pump runs but delivers only a small amount of water Pump is air locked Start and stop several times by plugging and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high or pipe size is too small Reduce vertical distance or increase the pip...

Отзывы: