Limitations: 

This series of pumps are suitable to pump rain water and also can be used both for permanent and 
temporary installation. 
The pump can be place for sump pit that means it could pump dirty water containing suspended solid 
particles 19mm/ 3/4inches diameter. 

(The screen size is 8mm/ 1/3inches).

 

 

! WARNING :

 

The pump cannot be used for sea water and flammable, corrosive, explosive or dangerous 

liquids. 

 

Installation :

 

! WARNING : 

Do not work on pump until power is unplugged.   

Do not cut off ground pin or use an adapter fitting.                                             
Do not use an extension cord 

 
The pump power cord should be connected to a separately fused, grounded line with a minimum capacity 
of 15 amps. It can be connect to non- fuse breaker at the recommended amperes. Never touch the pump 
when it is connected to electrical power. 

 
1.  Before installing or servicing this pump, be certain pump power source is disconnected. 
2.  Installation and electrical wiring must adhere to state and local codes and must be completed before 

priming pump. Check appropriate community agencies, or contact local electrical and pump 
professionals. 

3.  Call an electrician when in doubt. Pump should be connected to a separate 15 amps' circuit breaker or 

15 amps' fuse block. Note that, plugging into existing outlets may cause low voltage at motor,   
causing blown fuses, tripping of motor overload, or burned out motor. 

4.  A permanent ground connection from pump to the grounding bar at the service panel is mandatory,   

 Matala Pump sump pumps come with a grounding conductor and a grounding-type attachment plug. 

Do not connect pump to a power supply until permanently grounded. For maximum safety, connect 
pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the 
pump's grounding wire. 

5.  Voltage of power supply must match the voltage of the pump. 
6.  Before installing pump, clear sump basin of any water, debris, or sediment. 
       

! WARNING : 

Sump basin must be vented in accordance with local plumbing codes. Matala Sump 

pumps are not designed for and CANNOT be installed in locations classified as 
hazardous. 

7. 

! WARNING : 

The following may cause severe damage to pump and will void warranty: 

           

 

(a) Using an extension cord. 

              (b) Cutting off the ground pin or using an adapter fitting. 

(c) Working on pump or switch while plugged in. 
(d)  Removing motor housing, unscrewing impeller, or otherwise removing impeller seal. 
(e)  Pumping chemicals or corrosive liquids. 
(f)  Pumping gasoline or other flammable liquids. 
(g)  Piping: Plastic PVC pipe, drain hose, galvanized steel or copper pipe may all be used. 

All piping must be clean and free of all foreign matter to prevent clogging. Use thread 
compound on all threaded joints unless specified otherwise. Be sure to seal the 
thread connection with tape seal when you using the pipe fitting to connect the flange. 

 

Electrical Wiring                                                                                            __          _ 

 
Electrical wire Connection : 

! WARNING : 

Verify that the voltage and frequency of the electric pump shown on the nameplate 

correspond to those available on the mains. 

                     

The installer must make sure that the electric system is grounded in accordance with the law 
in force. 

 
It is necessary to use cable with a length of 10m for outdoors using. The plug and connections should be 
protected from water splashes. Before using the pump, always inspect it visually (especially power cable 
and plug). 
 
 
 
 
 

Содержание GM-3900

Страница 1: ...ax Flow Series Waterfall Pump This instruction manual explains the product operations and gives important precautions regarding its safe use In order to use the product to maximum benefit be sure to read the instructions thoroughly and follow them carefully To avoid accident do not use the pump in any way other than as described in this instruction manual especially when you see WARNING After read...

Страница 2: ...IL C60 1 19 O RING NBR 1 5 LOWER BEARING COVER FC200 1 20 PACKING NBR 1 6 OIL SEAL COVER NYLON 30 GF 1 21 SCREW SUS304 1 NYLON 30 GF for 22 STRAINER NYLON 30 GF 1 GM3900 GM4700 23 PUMP FEET SHEATH NBR 1 SUS430 PU for 24 WASHER SUS304 1 GM5400 GM6200 25 WASHER SUS304 1 8 UPPER PUMP CASING NYLON 30 GF 1 26 NUT SUS304 1 9 LOWER PUMP CASING PP 30 GF 1 27 KEY SUS304 1 10 CAPACITOR 1 28 SCREW SUS304 8 1...

Страница 3: ...se of your pump Other specifications are noted in the chart below Dimension Weight Hp W Inch mm Head Ft M Flow GPH LPH Head Ft M Flow GPH LPH L x W x H Inch mm lb kg GM 3900 1 5 150 1 1 2 38 11 5 2026GPH 22 5 3900GPH 9 4x6 5x14 240 165 355mm 15 4 7 GM 4700 1 3 250 2 50 13 3480GPH 27 5 4700GPH 9 4x6 5x14 240 165 355mm 15 4 7 GM 5400 1 2 400 2 50 16 3600GPH 32 8 5400GPH 9 4x6 5x14 8 240 165 375mm 17...

Страница 4: ...equipment out of the reach of children Warns that the failure to follow the directions given could cause serious risk to individuals or objects WARING This sign warns the operator that the failure to follow an instruction may damage the pump and or the system WARNING ...

Страница 5: ...o not connect pump to a power supply until permanently grounded For maximum safety connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the pump s grounding wire 5 Voltage of power supply must match the voltage of the pump 6 Before installing pump clear sump basin of any water debris or sediment WARNING Sump basin must be vented in accordance with loc...

Страница 6: ...curred by any customer in removing and or reaffixing any Matala Pump product parts or component THE WARRANTY WILL NOT APPLY a to defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and the parts used in connection wi...

Страница 7: ...reely in basin Defective float switch Replace with float switch Defective vertical switch Replace with vertical switch Pump runs but delivers only a small amount of water Pump is air locked Start and stop several times by plugging and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high or pipe size is too small Reduce vertical distance or increase the pip...

Отзывы: