MAT Industries 40CF16 Скачать руководство пользователя страница 8

8

Speedaire Operating Instructions

E

N

G

L

I

S

H

Assembly / Installation

Assembling the Compressor

Installation

The air compressor 
should be turned 

off, unplugged from the power source, 
the air bled from the tank and the 
unit allowed time to cool before any 
maintenance is performed. Personal 
injuries could occur from moving parts, 
electrical sources, compressed air or hot 
surfaces. The quick connect assembly 
must be attached before use. Failure to 
assemble correctly could result in leaks 
and possible injury. 
If unsure of assembly instructions or 
you experience difficulty in the assembly 
please call your local service department 
for further information.

1.  Unpack the air compressor. Inspect  
 

the unit for damage. If the unit has   

 

been damaged in transit, contact    

 

the carrier and complete a damage  

 

claim. Do this immediately because  

 

there are time limitations to damage  

 claims.

2.  Check the compressor’s serial label  
 

to ensure that you have received the  

 

model ordered, and that it has the   

 

required pressure rating for its  

 

 

intended use.

3.  Locate the compressor according to  
 

the following guidelines:

 

a.  Position the compressor near   

 

 

a grounded electrical outlet.

 

b.  The compressor must be at    

 

 

least 12 inches (31 cm) from    

 

 

any wall or obstruction, in a    

 

 

clean, well-ventilated area, to   

 

 

ensure sufficient air flow and   

  cooling.
 

c.  In cold climates, store portable  

 

 

compressors in a heated  

 

 

 

building when not in use. This  

 

 

will reduce problems with  

 

 

 

motor starting and freezing of  

  water 

condensation.

  

d.  Remove the compressor from   

 

 

the carton and place it on the   

 

 

floor or a hard, level surface.    

 

 

The compressor must be level  

 

 

to ensure proper drainage of 

 

 

the moisture in the tank.

Location of the Air Compressor

The air compressor should always be 

located in a clean, dry and well ventilated 

environment. The unit should have at  

minimum, 12 inches of space on each 

side. The air filter intake should be free 

of any debris or obstructions. Check the 

air filter on a daily basis to make sure it is 

clean and in working order.

Risk Of Fire Or Explosion

 

This product incorporates snap action 
switch contacts and a universal electric 
motor which tends to produce arcs 
and sparking and therefore should not 
be exposed to flammable liquids or 
vapors. This product is not intended 
for installation or use in a commercial 
garage or shop environment.

Grounding Instructions

This product must be grounded. In 
the event of an electrical short circuit, 
grounding reduces the risk of electric 
shock by providing an escape wire 
for the electric current. This product 
is equipped with a cord having a 
grounding wire with an appropriate 
grounding plug. (See Figure 3.) The 
plug must be plugged into an outlet 
that is properly installed and grounded 
in accordance with all local codes and 
ordinances. Check with a qualified 
electrician or service personnel if 
these instructions are not completely 
understood or if in doubt as to whether 
the tool is properly grounded.

Improper installation of the 
grounding plug will result 
in a risk of electric shock. 
If repair or replacement 
of the cord or plug is necessary, do 
not connect the grounding wire to 
either flat blade terminal. The wire with 
insulation having an outer surface that 
is green with or without yellow stripes 
is the grounding wire. Substitution 
of the signal word “

DANGER

” for 

WARNING

” is not prohibited when 

the risk associated with the product is 
such that a situation exists which if not 
avoided will result in death or serious 
injury.

 

Check with a qualified electrician 

or serviceman if the grounding 
instructions are not completely 
understood, or if in doubt as to whether 
the product is properly grounded. Do 
not modify the plug provided; if it will 
not fit the outlet, have the proper outlet 
installed by a qualified electrician.
This product is for use on a nominal 
120-V circuit and has a grounding plug 
similar to the plug illustrated in (Figure 
3). Only connect the product to an outlet 
having the same configuration as the 
plug. Do not use an adapter with this 
product.

Extension Cords

Use only a 3-wire extension cord that 
has a 3-blade grounding plug, and a 
3-slot receptacle that will accept the 
plug on the product. Make sure your 
extension cord is in good condition. 
When using an extension cord, be 
sure to use one heavy enough to carry 
the current your product will draw. 
Cords must not exceed 50 feet and 
No. 12 AWG size must be used. An 
undersized cord will cause a drop in line 
voltage resulting in loss of power and 
overheating.

Break In Procedures

No break in procedure is required 
by the user. This product is factory 
tested to ensure proper operation and 
performance.

Figure 3

Grounded Outlet 
Box

Grounded Outlet

Plug

Grounding Pin

120 VOLTS

Содержание 40CF16

Страница 1: ...esult in personal injury and or property damage Retain instructions for future reference Speedaire 15 Gallon 1 7HP 225 PSI Oil Free UMC Air Compressor For General Questions 1 800 GRAINGER For Warranty Service 1 888 895 4549 Do Not Return To Branch CAUTION Before using this product read this manual and follow all its Safety Rules and Operating Instructions Safety Instructions Installation Operation...

Страница 2: ...s render this warranty null and void The following components are considered normal wear items and are not covered after the first year of ownership Belts sheaves flywheels check valves pressure switches air unloaders throttle controls electric motors brushes regulators o rings pressure gauges tubing piping fittings fasteners wheels quick couplers gaskets seals air filter housings piston rings con...

Страница 3: ...essor and other components material pump spray guns filters lubricators hoses etc used make up a high pressure pumping system the following safety precautions must be observed at all times 1 Read all manuals included with this product carefully Be thoroughly familiar with the controls and the proper use of the equipment 2 Follow all local electrical and safety codes as well as the United States Na...

Страница 4: ...hildren s toys footballs basketballs etc It is normal for electrical contacts within the motor and pressure switch to spark Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If electrical sparks from compressor come into contact with flammable vapors they may ignite causing fire or explosion If spraying flammable materials locate compr...

Страница 5: ...rious injury Any repairs required on this product should be performed by authorized service center personnel Unsafe op er a tion of your compressor could lead to se ri ous in ju ry or death to you or others Review and understand all instructions and warnings in this manual The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt chips loose particles and small obj...

Страница 6: ...ingle Phase 60 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Gallon 15 56 8 liters Maximum Air Pressure 225 PSI Approximate Cut in Pressure 175 PSIG Approximate Cut out Pressure 225 PSIG SCFM 40 PSI 6 8 SCFM 90 PSI 5 1 NPT National Pipe Thread A seal thread tape must be used to provide a leak free seal on pipe threaded connections Pressure Regulator Knob Regulat...

Страница 7: ...and removing the air hose Check Valve When the pump is not in operation the valve closes to retain air pressure inside the tank An internal component Power Switch This controls the power to the motor and also the cut in cut out pressure settings This switch serves as the Auto On Off positions for the unit Tank Safety Valve Used to allow excess tank pressure to escape into the atmosphere This valve...

Страница 8: ...ntended for installation or use in a commercial garage or shop environment Grounding Instructions This product must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug See Figure 3 The plug must be plug...

Страница 9: ...air hose push the collar back on the quick connect socket C 5 Plug the power cord into the proper receptacle D 6 Turn the Power Switch to the On position and the compressor will start and build air pressure in the tank to cut out pressure and then shut off automatically A 7 Adjust the regulator to a PSI setting that is needed for your application and be sure it is within the safety standards requi...

Страница 10: ...he air pressure in the system and open the drain valve on the bottom of the tank and tilt tank to drain NOTE In cold climates drain the tank after each use to reduce problems with freezing of water condensation Checking the Safety Valve Figure 5 Check the safety valve by performing these three steps 1 Plug the compressor in and run until shut off pressure is reached 2 Wearing safety glasses pull o...

Страница 11: ... accessories are rated at 25 of actual CFM while running continuously Pressure relief valve opens Tank pressure exceeded normal operating pressure Replace pressure switch Pressure switch stuck Replace pressure switch Motor will not run Tank pressure exceeds preset pres sure switch limit Motor will start automatically when tank pressure drops below cut in pressure of pressure tank Make sure the The...

Страница 12: ...ing Pump Motor Assembly REF NO PART NO DESCRIPTION QTY 1 E106663 Pulley 1 2 E106664 Belt 1 3 E107844 Fan 1 4 E106666 Screw 1 5 E106667 Flywheel 1 6 E106668 Screw 1 7 E106669 Screw 4 8 E106670 Valve Plate Kit 1 9 E107845 Conrod Kit 1 10 E106672 Head 1 PARTS LIST ...

Страница 13: ...13 Speedaire Operating Instructions E N G L I S H Parts Drawing C151G ...

Страница 14: ...658 ZIP TIE 1 21 E106630 LABEL HOT SURFACE 1 22 E106631 LABEL WARNING DRAIN TANK 1 23 E106632 FILTER ASSEMBLY 1 24 E106633 SWITCH ROCKER 1 25 E106634 BRACKET 1 26 E107852 PRESSURE SWITCH 1 27 E106655 HOSE 1 28 E106637 ASSY WIRE JUMPER 1 29 E106638 SCREW 1 30 E107853 PUMP 1 31 E106640 NUT 2 32 E106641 ASSY NUT SLEEVE 1 2 1 33 E106661 ISOLATOR 2 34 E106643 SCREW 2 35 E106644 DRAIN VALVE 1 36 E107855...

Отзывы: