MAT Industries 40CF16 Скачать руководство пользователя страница 3

3

Speedaire Operating Instructions

E

N

G

L

I

S

H

Description

This manual contains information that is important for you to know and understand. This information relates to protecting YOUR 

SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read 

the manual and pay attention to these symbols.

Safety Symbols

Indicates an imminently 

hazardous situation which, if not avoided, 
will result in death or serious injury.

Indicates a potentially 

hazardous situation which, if not avoided, 
could result in death or serious injury.

Indicates a potentially 

hazardous situation which, if not avoided, 
MAY result in minor or moderate injury.

Indicates important 

information, that if not followed, may 
cause damage to equipment.

Unpacking

After unpacking the unit, inspect carefully for 
any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service.

Do not operate unit if damaged during 
shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.

General Safety Information

CALIFORNIA PROPOSITION 65 
WARNING: 

This product contains 

chemicals known to the State of 

California to cause cancer, birth defects 

and/or reproductive harm.

This product contains 

chemicals known to the State of California 
to cause cancer, and birth defects or other 
reproductive harm. Wash hands after 
handling.

Some dust contains 

chemicals known to the State of California 
to cause cancer, birth defects or other 
reproductive harm such as asbestos and 
lead in lead based paint

 To reduce 

the risk of injury, read the 
instruction manual.

GENERAL SAFETY

Since the air compressor and other 
components (material pump, spray guns, 
filters, lubricators, hoses, etc.) used, make 
up a high pressure pumping system, the 
following safety precautions must be 
observed at all times:
1.  Read all manuals included with this  

 

  product carefully. Be thoroughly familiar  
  with the controls and the proper use of the  
 equipment.
2.  Follow all local electrical and safety  

 

  codes as well as the United    

 

  States National Electrical Codes  

 

  (NEC) and Occupational Safety and Health  
  Act (OSHA). 
3.  Only persons well acquainted with these  
  rules of safe operation should be allowed  
  to use the compressor.
4.  Keep visitors away and NEVER allow    
  children in the work area.
5.  Wear safety glasses and use hearing    
  protection when operating the unit.
6.  Do not stand on or use the unit as a    
 handhold.
7.   Before each use, inspect compressed air  
  system and electrical components  

 

  for signs of damage, deterioration,  

 

  weakness or leakage Repair or replace   
  defective items before using.
8.  Check all fasteners at frequent intervals  
  for proper tightness.

Breathable Air Warning

This compressor/pump is NOT

equipped and should NOT be used

“as is” to supply breathing quality

air. For any application of air for

human consumption, you must fit

the air compressor/pump with suitable

in-line safety and alarm equipment.

This additional equipment is

necessary to properly filter and purify

the air to meet minimal specifications

for Grade D breathing as described 

in Compressed Gas Association 

Commodity Specification G 7.1 - 

1966, OSHA 29 CFR 1910. 134, and/

or Canadian Standards Associations 

(CSA).
DISCLAIMER OF WARRANTIES

In the event the compressor is used

for the purpose of breathing air

application and proper in-line safety

and alarm equipment is not 

simultaneously used, existing 

warranties are void, and Dayton 

Electric Mfg. Co. disclaims any liability 

whatsoever for any loss, personal 

injury or damage.

General Safety Rules

Содержание 40CF16

Страница 1: ...esult in personal injury and or property damage Retain instructions for future reference Speedaire 15 Gallon 1 7HP 225 PSI Oil Free UMC Air Compressor For General Questions 1 800 GRAINGER For Warranty Service 1 888 895 4549 Do Not Return To Branch CAUTION Before using this product read this manual and follow all its Safety Rules and Operating Instructions Safety Instructions Installation Operation...

Страница 2: ...s render this warranty null and void The following components are considered normal wear items and are not covered after the first year of ownership Belts sheaves flywheels check valves pressure switches air unloaders throttle controls electric motors brushes regulators o rings pressure gauges tubing piping fittings fasteners wheels quick couplers gaskets seals air filter housings piston rings con...

Страница 3: ...essor and other components material pump spray guns filters lubricators hoses etc used make up a high pressure pumping system the following safety precautions must be observed at all times 1 Read all manuals included with this product carefully Be thoroughly familiar with the controls and the proper use of the equipment 2 Follow all local electrical and safety codes as well as the United States Na...

Страница 4: ...hildren s toys footballs basketballs etc It is normal for electrical contacts within the motor and pressure switch to spark Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If electrical sparks from compressor come into contact with flammable vapors they may ignite causing fire or explosion If spraying flammable materials locate compr...

Страница 5: ...rious injury Any repairs required on this product should be performed by authorized service center personnel Unsafe op er a tion of your compressor could lead to se ri ous in ju ry or death to you or others Review and understand all instructions and warnings in this manual The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt chips loose particles and small obj...

Страница 6: ...ingle Phase 60 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Gallon 15 56 8 liters Maximum Air Pressure 225 PSI Approximate Cut in Pressure 175 PSIG Approximate Cut out Pressure 225 PSIG SCFM 40 PSI 6 8 SCFM 90 PSI 5 1 NPT National Pipe Thread A seal thread tape must be used to provide a leak free seal on pipe threaded connections Pressure Regulator Knob Regulat...

Страница 7: ...and removing the air hose Check Valve When the pump is not in operation the valve closes to retain air pressure inside the tank An internal component Power Switch This controls the power to the motor and also the cut in cut out pressure settings This switch serves as the Auto On Off positions for the unit Tank Safety Valve Used to allow excess tank pressure to escape into the atmosphere This valve...

Страница 8: ...ntended for installation or use in a commercial garage or shop environment Grounding Instructions This product must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug See Figure 3 The plug must be plug...

Страница 9: ...air hose push the collar back on the quick connect socket C 5 Plug the power cord into the proper receptacle D 6 Turn the Power Switch to the On position and the compressor will start and build air pressure in the tank to cut out pressure and then shut off automatically A 7 Adjust the regulator to a PSI setting that is needed for your application and be sure it is within the safety standards requi...

Страница 10: ...he air pressure in the system and open the drain valve on the bottom of the tank and tilt tank to drain NOTE In cold climates drain the tank after each use to reduce problems with freezing of water condensation Checking the Safety Valve Figure 5 Check the safety valve by performing these three steps 1 Plug the compressor in and run until shut off pressure is reached 2 Wearing safety glasses pull o...

Страница 11: ... accessories are rated at 25 of actual CFM while running continuously Pressure relief valve opens Tank pressure exceeded normal operating pressure Replace pressure switch Pressure switch stuck Replace pressure switch Motor will not run Tank pressure exceeds preset pres sure switch limit Motor will start automatically when tank pressure drops below cut in pressure of pressure tank Make sure the The...

Страница 12: ...ing Pump Motor Assembly REF NO PART NO DESCRIPTION QTY 1 E106663 Pulley 1 2 E106664 Belt 1 3 E107844 Fan 1 4 E106666 Screw 1 5 E106667 Flywheel 1 6 E106668 Screw 1 7 E106669 Screw 4 8 E106670 Valve Plate Kit 1 9 E107845 Conrod Kit 1 10 E106672 Head 1 PARTS LIST ...

Страница 13: ...13 Speedaire Operating Instructions E N G L I S H Parts Drawing C151G ...

Страница 14: ...658 ZIP TIE 1 21 E106630 LABEL HOT SURFACE 1 22 E106631 LABEL WARNING DRAIN TANK 1 23 E106632 FILTER ASSEMBLY 1 24 E106633 SWITCH ROCKER 1 25 E106634 BRACKET 1 26 E107852 PRESSURE SWITCH 1 27 E106655 HOSE 1 28 E106637 ASSY WIRE JUMPER 1 29 E106638 SCREW 1 30 E107853 PUMP 1 31 E106640 NUT 2 32 E106641 ASSY NUT SLEEVE 1 2 1 33 E106661 ISOLATOR 2 34 E106643 SCREW 2 35 E106644 DRAIN VALVE 1 36 E107855...