D. Transportation and Placement 

 

1.

 

Care required during transportation or movement of the unit 

 

Once unplugged from the power source, the unit should not be re-started for at 
least 10 minutes 

 

To prevent possible compressor damage, the cabinet should not be tilted at an 
angle greater than 45 degrees  

 

If the cabinet has been tilted greater than 45 degrees, stand upright for at least 1 
hour before re-starting 

 

Take good care of the glass panels to prevent breakage 

 

2.

 

Unpacking 

 

Carefully remove packaging and place the cabinet on a firm and level surface 

 

3.

 

Keep away from heat 

 

Keep the unit out of the direct sun or other heat source to ensure correct 
temperatures are achieved 

 

4.

 

Keep away from moisture 

 

The unit should never be placed where rain or water could impinge on it. Very 
high humidity may also affect the performance 

 

5.

 

Good ventilation 

 

The space between the cabinet and any wall should be at least 10 cm. Do not 
place stickers or the like over any part of the lower grilles, otherwise the unit will 
not achieve the correct temperature. Similarly, take care when deciding a position 
for the cabinet that other refrigeration equipment or similar is not blowing hot air 
at the unit. 

 

 
E. Safety 

 

The cabinet should ideally be connected to a separate electrical, 10 amp circuit 
with its own circuit breaker or fuse 

 

Do not use “double adapters” or similar devices which allow numbers of electrical 
appliances to be operated from on electrical outlet 

 

Ensure that no damage has been done to the electrical power lead or plug during 
transportation 

 

  Do not use water sprays or aerosol can sprays to clean the cabinet  

 

  Should the cabinet be disconnected from its power source, do not attempt to re-   

start for at  least 10 minutes 

 

Do not place objects on top of the cabinet 

 
 

 

3

Содержание BSF-170

Страница 1: ...S Se er rv vi ic ce e w w w m a s t r o s h o p c o m Mastro GmbH Hüserstraße 53 59075 Hamm Germany 49 0 2381 97371 0 49 0 2381 97371 88 ...

Страница 2: ...Operation Instruction Manual FOUR GLASS REFRIGERATED SHOWCASE ...

Страница 3: ... Please read this manual firstly before operating machine Please take care of this manual for ready use at any time 1 ...

Страница 4: ...g the door are double glazed and the outer panel has been coated with a heat reflecting film that assists in maintaining temperature and efficient operation 4 The four glass panels provide an excellent product display 5 Overall the cabinet has been designed to have an appealing look and is ideal for use as an impulse merchandiser B Construction and Part Names C Standards E3 Equipment performance s...

Страница 5: ...igh humidity may also affect the performance 5 Good ventilation The space between the cabinet and any wall should be at least 10 cm Do not place stickers or the like over any part of the lower grilles otherwise the unit will not achieve the correct temperature Similarly take care when deciding a position for the cabinet that other refrigeration equipment or similar is not blowing hot air at the un...

Страница 6: ...nsure the door is properly closed at all times If not the evaporator coil will build up with ice and your cabinet will not function correctly Try to educate your customer to make a choice before opening the door rather than holding the door open whilst making a choice This will also assist in the cabinet maintaining the correct temperature 3 Air Circulation Internally when loading your cabinet all...

Страница 7: ... supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard The appliance must be positioned that the plug is accessible J Specifications Models BSF 170 BSF 170 BSF 170 BSF 170 Capacity L 55 70 85 95 Climate type N N N N Temperature range 2 10 C 2 10 C 2 10 C 2 10 C Power supply 220V 50Hz 220V 50Hz 220V 50Hz 220V 5...

Отзывы: