TROUBLE SHOOTING
EN / WHISPER 3.5 / December 2009 / Copyright © 2009 Mastervolt
25
5.1.2
Failure or warning messages displayed on the remote control panel
AC warnings and
failures
Meaning
What to do?
No failure
None (no failure detected)
--
UAC Low
Generator output voltage too low
See section 5.1.3,
UAC High
Generator voltage too high
See section 5.1.3,
IAC High
AC output current is too high
Reduce connected load or see section 5.1.3,
FAC Low
AC output frequency is too low, engine speeds is
too low.
See section 5.2.3.
FAC High
AC output frequency is too high, engine speed is
too high.
See section 5.2.3.
Overload
Too much load connected to the AC output of
the generator
Reduce connected load or see section 5.1.3,
DC warnings and
failures
Meaning
What to do?
No failure
None (no failure detected)
--
UDC Bat low
Battery voltage of the starter battery is too low
(flat battery),
Check battery voltage. Recharge the battery,
check battery charger. Inspect battery
terminals and cables for a good electrical
connection (inspect against corrosion, tattered
wires, etc.)
Charger failure
Defective charger, charger fuse blown
Check battery charger, check charger fuse
Charger temp.
Internal temperature of battery charger circuit on
local control panel too high
Check battery charger
IDC Fuel high
DC current through the fuel lift pump was too
high
Check fuel lift pump, check fuel valve. Check
for short circuit in wiring
IDC Stop high
DC current through the pull to stop relay was too
high
Check pull to stop relay. Check for short circuit
in wiring
IDC Glow high
DC current through the glow plug was too high
Check glow plug. Check for short circuit in
wiring
IDC Start high
DC current through the start solenoid was too
high
Check start solenoid. Check wiring to start
solenoid. Check for short circuit in wiring
UDC Fuel high
DC voltage to the fuel lift pump was too high
Check whether no external DC source is
connected to wiring to the fuel lift pump.
UDC Stop high
DC voltage to the pull to stop relay was too high
Check wiring to of pull to stop relay.
UDC Glow high
DC voltage to the glow plug was too high
Check whether no external DC source is
connected to wiring to the glow plug.
UDC Start high
DC voltage to the start solenoid was too high
Check whether no external DC source is
connected to wiring to the start solenoid.
UDC Fuel low
DC voltage to the fuel lift pump was too low
Check for short circuits in the fuel lift pump,
check for short circuits in the wiring.
UDC Stop low
DC voltage to the pull to stop relay was too low
Check for short circuits in the pull to stop relay,
check for short circuits in the wiring.
UDC Glow low
DC voltage to the glow plug was too low
Check for short circuits in the glow plug, check
for short circuits in the wiring.
UDC Start low
DC voltage to the start solenoid was too low
Check for short circuits in the start solenoid,
check for short circuits in the wiring.
Содержание WHISPER 3.5M3000 RPM
Страница 35: ...SPARE PARTS LIST EN WHISPER 3 5 December 2009 Copyright 2009 Mastervolt 35 Figure 18 Waterpump type K...
Страница 37: ...NOTES EN WHISPER 3 5 December 2009 Copyright 2009 Mastervolt 37 NOTES...
Страница 38: ...NOTES 38 Copyright 2009 Mastervolt December 2009 WHISPER 3 5 EN NOTES...
Страница 39: ...NOTES EN WHISPER 3 5 December 2009 Copyright 2009 Mastervolt 39 NOTES...