– User and Installation Manual 

  

 

Events 

Description 

Value 

Event x 
source 

Event that triggers an 
action, e.g. Battery low 

See 

Event source

 

list 

Event x 
target 

Device that should act, 
e.g. the generator 

System dependent 

Event x 
command 

Parameter that must be 
changed on the target 
device, e.g. Activate 

See command list 
of the selected 
device 

Event x 
data 

Data is linked to the 
command 

Off, On, Copy, 
Copy Invert, Toggle 

The PowerCombi can be configured as an 

event source

An event source can be used to initiate an 

event command

 

and 

event action 

by another device that is connected to 

the MasterBus. 

Event source 

Description 

Power 

PowerCombi is switched on 

Overload 

Loads exceed nominal inverter power 

DC Low voltage  Main battery voltage has dropped 

below Low bat value 

Alarm 

PowerCombi alarm has been triggered 

AC IN 

AC input is present 

When the PowerCombi is configured as an 

event target

 by 

another device, this device can initiate an 

event command

 

and an 

event action

 to be performed by the PowerCombi.  

Event command 

Description 

Power 

Change PowerCombi on/off state 

5

 

TROUBLESHOOTING 

Problem 

Possible cause 

What to do? 

PowerCombi 
cannot be found 

Connected 
device is not set 
to remote control 

Switch the 
PowerCombi's main 
switch to position 

remote

 

Error in the wiring  Check the cables 

PowerCombi is 
switched off via 
interface but 
still consumes 
energy 

PowerCombi is 
set to 

on

 instead 

of 

remote

 

On the 
PowerCombi, 
switch the main 
switch to position

 

remote

 

No display 
function 

Display is 
switched off  

Switch on display, 
refer to display 
manual 

Error in the 
wiring. 

Check the 
MasterBus cables 

No powering 
device available 
on the MasterBus 

With AC power 
disconnected, the 
PowerCombi 
MasterBus Interface 
gets no power from 
the MasterBus 
network. At least 
one connected 
MasterBus device 
should have 
powering 
capabilities 

Problem 

Possible cause 

What to do? 

Slow or no 
MasterBus 
communication 

Error in the 
MasterBus wiring 

Check the 
MasterBus cables 

No terminator at 
the end(s) of the 
network 

MasterBus needs a 
terminator on both 
ends of the network 

MasterBus 
network is 
configured as ring 
network or has T-
connections 

Ring networks and 
T-connections are 
not allowed. Check 
the connections of 
the network 

6

 

SPECIFICATIONS 

Product code: 

77032900 

Delivery also includes: 

˗ 

MasterBus terminator 

˗ 

MasterBus cable 39inch [1m] 

˗ 

RJ11 straight cable 39inch [1m] 

˗ 

User and installation manual 

Languages available:  English 
Current consumption:   35mA 
MasterBus Powering:  No 
DIN rail mounting: 

Yes, DIN rail 1.2inch [30mm] 

Protection degree: 

IP 21 

Weight: 

0.15lb [70g] 

Dimensions: 

2.6 x 3.1 x 1.3inch  
[66 x 78 x 32mm] 

 

 

 

Dimensions in inches 

Copyright © 2020 Mastervolt. All rights reserved. 

 

Europe, Middle 
East & Africa

  

The Netherlands

 

Customer Service

 

T: +31(0)203422100 
E:

  

info@ 
mastervolt.com 

Technical Support  

T: +31(0)203422100 
E:

  

ts@ 
mastervolt.com

 

Americas & 
Caribbean

  

United States

 

Customer Service 

T: +1 800 307 6702 
E:

 

orderentry@ 
marinco.com 

Technical Support 

T: +1 800 307 6702 
E:

  

tsusa@ 
mastervolt.com

 

Asia Pacific

  

New Zealand

 

Customer Service 

T: +64 9 415 7261 
E:

  

enquiries@ 
bepmarine.com 

Technical Support 

T: +64 9 415 7261 
E:

  

technical@ 
bepmarine.com

 

 

Содержание MasterBus PowerCombi Interface

Страница 1: ...consequential damage due to use of the PowerCombi MasterBus Interface possible errors in the manuals and the results thereof use that is inconsistent with the purpose of the product Disclaimer Our products are subject to continual development and improvement Therefore additions or modifications to the products may cause changes to the technical data and functional specifications No rights can be d...

Страница 2: ...he PowerCombi 4 CONFIGURATION The following table lists the MasterBus monitoring functions as shown in MasterAdjust Monitoring Description Default Adjustable range General Device state The operation mode Off Charging Inverting Alarm Power saving Supporting Not applicable read only AC IN Limit Fuse setting of the AC input 15 3 30 Power button Button to switch off on the PowerCombi On On Off DC IN O...

Страница 3: ...l AGM User defined Bulk Voltage Maximum Bulk voltage adjustable if User Defined Flooded 14 40 28 80 Gel 14 40 28 80 AGM 14 40 28 80 User defined 14 40 28 80 12 00 16 00 12V 24 00 32 00 24V Read only when battery type is not User defined Maximum time Maximum time the bulk phase lasts before the charger changes to absorption 480min 30 1200 Read only when battery type is not User defined Absorption V...

Страница 4: ...witch to position remote No display function Display is switched off Switch on display refer to display manual Error in the wiring Check the MasterBus cables No powering device available on the MasterBus With AC power disconnected the PowerCombi MasterBus Interface gets no power from the MasterBus network At least one connected MasterBus device should have powering capabilities Problem Possible ca...

Отзывы: