PowerCombi MasterBus Interface
–
User and Installation Manual
3
The following table shows the PowerCombi configuration settings.
Configuration
Description
Default
Adjustable range
Device
Language
Language displayed on monitoring
device connected to PowerCombi
English
Read-only
Name
Name of the PowerCombi in
MasterBus
PowerCombi
Free text with a max. of 12
characters
Type
PowerCombi type
12V/1200W-50A or
12V/2000W-100A
Read-only
Inverter
Energy save mode Option to enable Energy save mode
Off (not checked)
Off. On
Frequency
Output frequency
60Hz
60Hz
Voltage
AC voltage
115V
100 - 120
DC low off
Low battery voltage at which the
inverter switches off
10.0V /
20.0V
10.00-11.50 (12V)
20.00-23.00 (24V)
DC low on
Low battery inverter switch on
voltage at DC Low off alarm
11.5V /
23.0V
10.00-14.50 (12V)
20.00-29.00 (24V)
DC high off
High battery voltage for inverter
switch off
15.5V /
31.0V
15.00-16.50 (12V)
30.00-33.00 (24V)
DC high on
High battery voltage for inverter
switch to DC High Off alarm
15.0V /
30.0V
13.00-16.50 (12V)
26.00-33.00 (24V)
Charger
Max charge cur.
Maximum charging current
adjustable.
50A /
100A
13-50 (12V/1200W-50A)
25-100 (12V/2000W-100A)
6-25 (24V/1200W-25A)
13-50 (24V/2000W-50A)
Battery type
Select the main battery type.
Flooded (Lead acid)
Flooded, Gel, AGM, User defined
Bulk
Voltage
Maximum Bulk voltage (adjustable if
User Defined).
Flooded: 14.40 / 28.80
Gel: 14.40 / 28.80
AGM: 14.40 / 28.80
User defined: 14.40 / 28.80
12.00-16.00 (12V)
24.00-32.00 (24V)
Read-only when battery type is
not User defined
Maximum time
Maximum time the bulk phase lasts
before the charger changes to
absorption.
480min
30-1200
Read-only when battery type is
not User defined
Absorption
Voltage
Absorption voltage (adjustable if User
Defined is selected.
14.25V /
28.50V
12.00-16.00 (12V)
24.00-32.00 (24V)
Read-only when battery type is
not User defined
Maximum time
Maximum time that the charger stays
in absorption mode.
240min
30-600
Float settings
Voltage
Float voltage (adjustable if User
Defined).
Flooded: 13.25/26.50
Gel: 13.80/27.60
AGM: 13.80/27.60
User defined: 13.25/26.50
12.00-16.00 (12V)
24.00-32.00 (24V)
Read-only when battery type is
not User defined
AC IN
AC IN support
Allow AC support mode option
Off (not checked)
Off. On
DIP Switches
Position of the DIP switches
Not applicable
Read-only
A MasterBus device can be programmed to initiate an action at another connected device. This is very helpful in automation of
your system. In MasterBus this is done by means of event-based commands. In the Events tab you can program the
PowerCombi
to act as an event source. Events which occur during the operation of the
PowerCombi
will then trigger actions
from other products. The following tables list the parameters as shown in MasterAdjust.