Mass Sine Ultra
– Installation Manual Multiple Units
Parallel configuration with MasterAdjust
5
3 PARALLEL CONFIGURATION WITH MASTERADJUST
Up to 10 units may be set in parallel with MasterAdjust. Basic knowledge of MasterAdjust is required.
3.1
Materials needed
Description
Quantity
Multiple units (product code: 26024000)
n
MasterBus Terminator (included but not always needed)
MasterBus cables between units (product code e.g. 3 meter: 77040300)
n-1
Sync cables to interconnect all units (product code e.g. 3 meter: 6502000030)
n-1
MasterBus USB Interface (product code: 77030100)
1
Windows based PC with the MasterAdjust configuration tool
1
DC + cable with fuse
n
DC
– cable
n
AC cable to connect the AC input of the unit to an external power source (MSU) n
AC cable to connect the external load to
OUT
n
3.2
Preparations
-
Make sure that all power sources (AC and DC) are switched off.
-
Make sure that DIP switches 1 and 2 are off on all units.
DIP switch location
All
other DIP switches (3…8) on the Replica unit(s) must match the settings on the Primary unit. For an overview of DIP
switch settings, please see the user manual.