background image

 2   

 

Mass Sine Ultra 

– Installation Manual Multiple Units 

  

 

 

 

TABLE OF CONTENTS: 

1

 

GENERAL INFORMATION .............................................................................................................................................. 3

 

1.1

 

Use of this manual .............................................................................................................................................. 3

 

1.2

 

Validity of this manual......................................................................................................................................... 3

 

1.3

 

Purpose of a multiple configuration .................................................................................................................... 3

 

1.4

 

General installation guidelines ............................................................................................................................ 3

 

1.5

 

Overview Mass Sine Ultra .................................................................................................................................. 3

 

2

 

FLOWCHART .................................................................................................................................................................. 4

 

3

 

PARALLEL CONFIGURATION WITH MASTERADJUST ............................................................................................... 5

 

3.1

 

Materials needed ................................................................................................................................................ 5

 

3.2

 

Preparations ....................................................................................................................................................... 5

 

3.3

 

DC wiring of parallel units ................................................................................................................................... 6

 

3.4

 

AC wiring of parallel units ................................................................................................................................... 6

 

3.5

 

Network wiring of parallel units ........................................................................................................................... 7

 

3.6

 

Configuration with MasterAdjust ......................................................................................................................... 7

 

3.7

 

Initial start-up ...................................................................................................................................................... 9

 

4

 

PARALLEL CONFIGURATION WITH DIP SWITHES ................................................................................................... 10

 

4.1

 

Materials needed .............................................................................................................................................. 10

 

4.2

 

Preparation ....................................................................................................................................................... 10

 

4.3

 

DC wiring of parallel units ................................................................................................................................. 10

 

4.4

 

AC wiring of parallel units ................................................................................................................................. 11

 

4.5

 

Network wiring of parallel units ......................................................................................................................... 11

 

4.6

 

Configuration with DIP switches ....................................................................................................................... 11

 

4.7

 

Initial start-up .................................................................................................................................................... 12

 

5

 

THREE-PHASE CONFIGURATION WITH MASTERADJUST ...................................................................................... 13

 

5.1

 

Materials needed .............................................................................................................................................. 13

 

5.2

 

Preparations ..................................................................................................................................................... 13

 

5.3

 

DC wiring of three-phase units ......................................................................................................................... 13

 

5.4

 

AC wiring of three-phase units ......................................................................................................................... 14

 

5.5

 

Network wiring of three-phase units ................................................................................................................. 14

 

5.6

 

Configuration with MasterAdjust ....................................................................................................................... 14

 

5.7

 

Initial start-up .................................................................................................................................................... 16

 

6

 

TROUBLESHOOTING ................................................................................................................................................... 17

 

 

Содержание MASS SINE ULTRA

Страница 1: ...MULTIPLE UNITS MASS SINE ULTRA Parallel or three phase configurations INSTALLATION MANUAL 10000019321 00...

Страница 2: ...iring of parallel units 7 3 6 Configuration with MasterAdjust 7 3 7 Initial start up 9 4 PARALLEL CONFIGURATION WITH DIP SWITHES 10 4 1 Materials needed 10 4 2 Preparation 10 4 3 DC wiring of parallel...

Страница 3: ...can be made available 1 4 General installation guidelines When using units in a multiple unit configuration the following requirements are applicable in addition to the requirements mentioned in the...

Страница 4: ...the 3 phase with MasterAdjust installation procedure Start 3 Phase More than 2 units Lithium Ion Batteries Click here or go to page 5 for the parallel with MasterAdjust installation procedure YES Para...

Страница 5: ...es to interconnect all units product code e g 3 meter 6502000030 n 1 MasterBus USB Interface product code 77030100 1 Windows based PC with the MasterAdjust configuration tool 1 DC cable with fuse n DC...

Страница 6: ...ection Inline fuse Recommended battery bank Indicated cable sizes are for cables from unit to busbar and shorter than 3m Cables from busbar to battery bank should be twice the diameter When cables are...

Страница 7: ...left pane of MasterAdjust right click the Primary unit and select Login The Primary unit is the device that has the AC OUT 2 connection The other units are called Replica units Note that in the older...

Страница 8: ...y Replica 15 Click the Select devices button to be able to select the Replica unit s 16 Notice the Cluster topology and Cluster state Topology monitors the size of the cluster whether the selected num...

Страница 9: ...ne of MasterAdjust the Replica unit s will now be listed under the Primary unit 3 7 Initial start up 1 Switch all units off and on again 2 Check that the units are working as inverter 3 Close the AC b...

Страница 10: ...e 2 AC cable to connect the AC input of the unit to an external power source MSU 2 AC cable to connect the external load to OUT 2 4 2 Preparation Make sure that all power sources AC and DC are switche...

Страница 11: ...are switched off 2 Make sure that all connections are firmly tightened Configuration 3 Use a small screwdriver to carefully set the DIP switches of block A DIP switch location Circuit Breaker no RCD R...

Страница 12: ...position 0 and set 2 on position 1 All other DIP switches 3 8 on the Replica unit must match the settings on the Primary unit For an overview of DIP switch settings please see the user manual 4 7 Init...

Страница 13: ...ble to connect the external load to OUT 3 5 2 Preparations Make sure that all power sources AC and DC are switched off Make sure that DIP switches A1 and A2 are off on all units DIP switch location Al...

Страница 14: ...onnect a MasterBus USB Interface to the MasterBus network and to a PC and open MasterAdjust Installation or configuration errors may come up in MasterAdjust while the configuration is in progress This...

Страница 15: ...for example must be configured for ALL units separately 12 In the Cluster pane from the Phase System drop down list select Three Phase You may need to maximize the MasterAdjust window or scroll all th...

Страница 16: ...ual to the selected number of devices State monitors the configuration state of the cluster Click the Activate cluster button to finish the cluster configuration The Cluster state will change from Inc...

Страница 17: ...erature Mass Sine Ultra too hot Restart when alarm is over Check ventilation Reduce load 1 and 3 red System error Sync error Config error Communication disturbed Configuration wrong Check communicatio...

Страница 18: ...Shipping Advanced Systems Group US N85 W12545 Westbrook Crossing Menomonee Falls Wisconsin 53051 United States Asia Pacific Customer Service T 64 9 415 7261 Option 1 E enquiries bepmarine com Technica...

Отзывы: