OPERATION
8
Copyright © 2010 Mastervolt / October 2010 / Mass Sine C1 / EN
“high temperature”
The Mass Sine switches off in case of high ambient
temperatures and /or sustained overload. The Mass Sine
is automatically powered up again when the temperature
drops below the factory default threshold.
Overheating is most likely caused by:
•
heavy or non-resistive loads operating for a longer time
•
high ambient temperature
•
disrupted air flow (dust or too less space)
3.4
REMOTE CONTROLLED OPERATION
If you use a remote control panel or interface (see section
4.4), the main switch on front of the Mass Sine must be set
to the ‘remote’ position. Move the main switch on the
remote control panel / interface to the ‘on’ position to
switch on the Mass Sine.
NOTE! When the main switch is in the “Off”-
position, it overrides the remote control panel /
interface. In this off state it is not possible to
start the Mass Sine remotely.
The meaning of the illuminated LED’s of the C4 RI panel
is:
inverter on:
Mass Sine is switched on
failure:
Mass Sine is overloaded, overheated or
battery voltage is too low
If the failure LED is lit you can check the nature of the
failure on the inverter front.
Refer to the applicable user’s manual for operation of the
other remote control panels or interfaces
3.5 MAINTENANCE
For a reliable and optimum function of the Mass Sine, the
following is required:
•
Check at least once a year if all cable and wire
connections are still firmly connected.
•
Keep the inverter dry, clean and dust-free, in order to
ensure good heat discharge.
•
Check the fan operation (has a life time of at least 10
years in normal use).
3.6 PROBLEM
SOLVING
Refer to chapter 5 if a problem occurs.