MAC-PLUS
31
Value
Meaning
Factory setting
Adjustable range
Remote sw. input
Mode
Acitve low: active if voltage
between 0-0.5 V, Active high:
active if voltage between 3-32
V, Not used: always active
Active high
Not used, Active
low, Active high
Input threshold
Enabled
Enabled: input voltage
thresholds are active
Disabled: input voltage
thresholds are not active
Enabled
Enabled, Disabled
Enable voltage
Enable input voltage
12.50 / 25.00 V
8-16 / 16-32 V
Enable delay
Enable delay
2 s
0-300 s
Disable voltage
Disable input voltage
12.00 / 24.00 V
8-16 / 16-32 V
Disable delay
Disable delay
300 s
0-300 s
Instant disable
Disable input voltage, no
delay
11.00 V
8-16 / 16-32 V
Sleep delay
Delay before the Mac Plus
switches to sleepmode
300 s
0-3600 s
Charger
Battery type
Selection of pre-set charge
algorithm. Individual
adjustments are only possible
if “User defined” is selected
here.
Flooded
Flooded, Gel,
AGM, Spiral, Li-
Ion, Traction,
NiCad, Constant
voltage, User
defined,
Max output
Maximum output (charge)
current
50 A
30 A
0-50 A
0-30 A
Max input
Maximum input current
50 A
30 A
0-50 A
0-30 A
Current ramp up
Charge current ramp up after
enabling the charger.
5 A/s
0-50 A/s
Temp. compensate
Temperature compensation
for charge voltage
-0.030 V/°C
-0.060 V/°C
-0.1 - +0.1 V
Value
Meaning
Factory setting
Adjustable range
Shunt
Shunt device
(available in upcoming
software update)
Selection of the shunt device to
which the Mac Plus is
connected. This can either be a
No connection
No connection,
MSH+Product
Name,
Содержание Mac Plus 12/24-30
Страница 2: ...2 MAC PLUS ...
Страница 8: ...8 MAC PLUS 4 Dimensions 146 mm 198 mm 255 mm 66 mm 165 mm ...
Страница 10: ...10 MAC PLUS 6 Identification label Identification label ...
Страница 13: ...MAC PLUS 13 Installation drawing A Installation drawing B ...
Страница 28: ...28 MAC PLUS Do not make ring networks Do not make T connections in the network ...
Страница 34: ...34 MAC PLUS ...
Страница 35: ...MAC PLUS 35 ...