6

INSTALLATION

OPERATION

BATTERIES

2 battery set

3 battery set

BI 702

BI 703

For a proper installation, see the connection diagram in-
cluded with the battery isolator. Steps:

1 Check if the charger, the main supply and the DC-

distribution are switched off.

2 Connect the battery isolator using cables with the same

diameter as the battery cables.

3 Compensate the voltage drop over these diodes by 

removing the “diode compensation” jumper on the front
of the charger.

4 Switch the charger on.

ADJUSTEMENTS
On the front side of the charger you find three jumpers,
each for a specific application. You can easily remove the
jumpers with a pincet or small pincer. Unplug the AC
power cord prior to removing or placing a jumper.

Forced float
For industrial applications only.

Gel/wet battery
By removing this jumper the output voltage will be a
constant “trickle charge” voltage of 13,8V.

Diode compensation
By removing this jumper the output voltage will be increased
with 0,7 Volt.

6

OPERATION

The IVO charger has no ON/OFF switch!

Switching on:
The IVO charger will be switched on by plugging in the
AC-power cord. One of the LED indicators will light up
now and the charger starts immediately.

Turning off:
The IVO charger will be switched off by unplugging this
power cord.

INDICATOR LEDS

FLOAT

The battery charger is in a “trickle charge”
mode, batteries are 100% charged.

ABSORPTION

The batteries are still being charged,
charge level is approx. 80%.

BULK

The charger supplies the maximal volta-
ge, the battery charge is less than 80%.

7

BATTERIES

DEFINITION OF THE BATTERY CAPACITY
Starting point is the consumption during a certain period
without charging the battery. It is recommended not
discharge the battery totally, but to keep 50% in spare. A
consistent deep discharging decreases the lifetime of the
battery. Take care of the reduced capacity on the end of
the battery life (average 70%) and the temperature.
According to abovementioned, the rule of thumb is: 
• amps use x 2 = battery capacity.

TIPS TO INCREASE THE BATTERY LIFETIME

• Install and place the batteries in a cool and well venti-

lated enviroment. The acid in the batteries will damage
the plates in a high tempe-rature environment. A lifetime
of 5 year at 68°F (20°C), will be 2,5 at 86°F (30°C).

• Charge the battery immediately after a consistent deep

discharge. Especially at high environment tempera-
tures, sulfating occurs very fast. If the state of sulfating
is not too bad, the battery will remain a part of his
capacity after a few charge / recharge cycles.

Содержание IVO SMART 12/30-2

Страница 1: ...al information 2 2 Safety guidelines measures 2 3 Technical data 3 4 Technology 3 5 Installation 4 6 Operation 6 7 Batteries 6 8 Trouble shooting 7 9 Maintenance 8 10 EC declaration of conformity 8 11...

Страница 2: ...d against rain moist dust and not condensing circumstances Never use the battery charger at locations where there is danger of gas or dust explo sion Use other than as mentioned under 2 is not conside...

Страница 3: ...battery charger rectifier developed and produced by Mastervolt Amsterdam The IVO series goes with a family of advanced quality battery chargers Mastervolt distribu tes these products worldwide The bat...

Страница 4: ...e char ger automatically switches back to a lower output voltage of 13 25V This voltage is sufficient to maintain the battery at a 100 charge During this phase the charge voltage can be entirely used...

Страница 5: ...rging current for the cranking battery is 3A The char ging current for the main battery will in this case be 3A less Connect the minus of the cranking battery to the minus of the main battery Connect...

Страница 6: ...and the charger starts immediately Turning off The IVO charger will be switched off by unplugging this power cord INDICATOR LEDS FLOAT The battery charger is in a trickle charge mode batteries are 10...

Страница 7: ...aximum charge current will be reduced automatically Mains too low When the mains voltage is less than 105V the charger will regulate the current down Batteries not fully charged Charge current too low...

Страница 8: ...RVOLT Address Snijdersbergweg 93 1105 AN AMSTERDAM The Netherlands Herewith declares that Product IVO battery charger Model IVO Smart 12 30 2 117V IVO Smart 12 50 2 117V Is in conformity with the prov...

Страница 9: ...ERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 APPENDIX A B V2 0 March 2004 IVO SMART 12 30 2 12 50 2 117 Volt battery charger export models U S A vers...

Страница 10: ...10 IVO Smart Appendix A...

Страница 11: ...factor 1 power factor controlled Max input power 540 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 30 Amps Charge characteristic three step fully automatic IUoUo programmable...

Страница 12: ...25 Iout 30 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Страница 13: ...blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power factor cor...

Страница 14: ...nd under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo ch...

Страница 15: ...actor 1 power factor controlled Max input power 850 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 50 Amps Charge characteristic three step fully automatic IUoUo programmable...

Страница 16: ...25 Iout 50 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Страница 17: ...nstallation blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power...

Страница 18: ...and under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo c...

Страница 19: ...set points can be adjusted in the charger by use of the adjustment interface The standard remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Type twisted wire...

Страница 20: ...ilure The DC alarm set points can be adjusted in the chargers by use of the adjustment interface The basic remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Ty...

Страница 21: ...ndard remote analogue jack smart basic remote panel temp sensor RS 232 forced to float gel wet type diode compensation 0 6V jumper selection main output 1 common min AC in start service service 1 Slav...

Страница 22: ...lure Inverter Control on failure float bulk absorption Charger Control Charger Output current control on failure float bulk absorption Charger Control on bulk charge failure float absorption Charger C...

Страница 23: ......

Страница 24: ...MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006...

Отзывы: