Mastervolt IVO SMART 12/30-2 Скачать руководство пользователя страница 18

18

IVO Smart Appendix A

DATA SHEETS

Set points register

Setpoint

1

Min. bulk time

min.

2

Temperature variation

5.0 

mV/C

3

Return to bulk time

30 

sec.

4

Return to bulk voltage

13.00  V

5

Max. bulk/abs time

360 

min.

6

Min. abs time

45 

min.

7

Return Amps

2.5 

Amps

8

Max. charge current

50

Amps

9

Bulk voltage

14.55 V

10

Abs voltage

14.35 V

11

Float voltage

13.30 V

12

Forced to float voltage

13.25 V

13

Gel voltage setting

55 

mV

14

Diode compensation setting

60 

mV

15

DC high alarm on

15.00  V

16

DC high alarm low

14.50 V

17

DC low alarm on

10.00 V

18

DC l ow alarm off

11.00 V

19

Alarm delay time

30

sec.

20

Reset data

WWYY

21

Battery identification no

00

• Temperature variation 

   5.0 mV/

°

C per cell

• Reference voltage 25

°

C

• Battery charging is not allowed 

   above +50

°

C and under -20

°

C

• 24 Volt    60 mV/

°

C               

5.0 mV/

°

C

Uref 25

°

C

forced floatgel/wet battery

diode compensation

standard IUoUo characteristic

IUoUo char. increased with 0.6V

IUoUo char. high float level

IUoUo char. high float, increased with 0.6

IU char. low float level

IU char. low float, increased with 0.6V

IU char. high float level

IU char. high float, increased with 0.6 V

TEMPERATURE COMPENSATED CHARGING

charging voltage in V

15.0

14.5

14.0

13.5

13.0

12.5

12.0

-30

-20

-10

0

10

20

30

40

50

60

battery temperature in 

°

C

float

absorption

25

°

C reference 

temperature

MAX. BULK/ABS TIME

BULK TIME
TOTAL CHARGE TIME CYCLE

ABS TIME

FLOAT TIME

NEW CYCLE

min. bulk time

min. abs time

return to bulk time

MAX. OUTPUT VERSUS INPUT VOLTAGE

current in 

Amps

input voltage

50

80

100

120

140

160

180

200

220

240

260

25

°

C reference

temperature

25

°

C reference

temperature

0

44

50

output current in Amps

Tamb= 25

°

C

charging voltage in V

CHARGING CHARACTERISTICS

Содержание IVO SMART 12/30-2

Страница 1: ...al information 2 2 Safety guidelines measures 2 3 Technical data 3 4 Technology 3 5 Installation 4 6 Operation 6 7 Batteries 6 8 Trouble shooting 7 9 Maintenance 8 10 EC declaration of conformity 8 11...

Страница 2: ...d against rain moist dust and not condensing circumstances Never use the battery charger at locations where there is danger of gas or dust explo sion Use other than as mentioned under 2 is not conside...

Страница 3: ...battery charger rectifier developed and produced by Mastervolt Amsterdam The IVO series goes with a family of advanced quality battery chargers Mastervolt distribu tes these products worldwide The bat...

Страница 4: ...e char ger automatically switches back to a lower output voltage of 13 25V This voltage is sufficient to maintain the battery at a 100 charge During this phase the charge voltage can be entirely used...

Страница 5: ...rging current for the cranking battery is 3A The char ging current for the main battery will in this case be 3A less Connect the minus of the cranking battery to the minus of the main battery Connect...

Страница 6: ...and the charger starts immediately Turning off The IVO charger will be switched off by unplugging this power cord INDICATOR LEDS FLOAT The battery charger is in a trickle charge mode batteries are 10...

Страница 7: ...aximum charge current will be reduced automatically Mains too low When the mains voltage is less than 105V the charger will regulate the current down Batteries not fully charged Charge current too low...

Страница 8: ...RVOLT Address Snijdersbergweg 93 1105 AN AMSTERDAM The Netherlands Herewith declares that Product IVO battery charger Model IVO Smart 12 30 2 117V IVO Smart 12 50 2 117V Is in conformity with the prov...

Страница 9: ...ERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 APPENDIX A B V2 0 March 2004 IVO SMART 12 30 2 12 50 2 117 Volt battery charger export models U S A vers...

Страница 10: ...10 IVO Smart Appendix A...

Страница 11: ...factor 1 power factor controlled Max input power 540 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 30 Amps Charge characteristic three step fully automatic IUoUo programmable...

Страница 12: ...25 Iout 30 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Страница 13: ...blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power factor cor...

Страница 14: ...nd under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo ch...

Страница 15: ...actor 1 power factor controlled Max input power 850 Watt Efficiency 81 Output voltage nominal 12V DC Output current nominal 50 Amps Charge characteristic three step fully automatic IUoUo programmable...

Страница 16: ...25 Iout 50 Amps at 77 F Tamb 25 C ELECTRO MAGNETIC COMPATBILITY Electro Magnetic Emission better than EN 50081 1 gen emmission standard scope residiential commercial light industry Electro Magnetic I...

Страница 17: ...nstallation blocks OPERATING PRINCIPLE Fully automatic power factor corrected switch mode battery charger suitable as power supply using a separate non isolated pre regulator boost converter for power...

Страница 18: ...and under 20 C 24 Volt 60 mV C 5 0 mV C Uref 25 C f o r c e d f l o a t g e l w e t b a t t e r y d i o d e c o m p e n s a t i o n standard IUoUo characteristic IUoUo char increased with 0 6V IUoUo c...

Страница 19: ...set points can be adjusted in the charger by use of the adjustment interface The standard remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Type twisted wire...

Страница 20: ...ilure The DC alarm set points can be adjusted in the chargers by use of the adjustment interface The basic remote panel Specifications Remote cable Connector RJ45 6 pole male Max length 6 meter max Ty...

Страница 21: ...ndard remote analogue jack smart basic remote panel temp sensor RS 232 forced to float gel wet type diode compensation 0 6V jumper selection main output 1 common min AC in start service service 1 Slav...

Страница 22: ...lure Inverter Control on failure float bulk absorption Charger Control Charger Output current control on failure float bulk absorption Charger Control on bulk charge failure float absorption Charger C...

Страница 23: ......

Страница 24: ...MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006...

Отзывы: