18
IVO Smart Appendix A
DATA SHEETS
Set points register
Setpoint
1
Min. bulk time
4
min.
2
Temperature variation
5.0
mV/C
3
Return to bulk time
30
sec.
4
Return to bulk voltage
13.00 V
5
Max. bulk/abs time
360
min.
6
Min. abs time
45
min.
7
Return Amps
2.5
Amps
8
Max. charge current
50
Amps
9
Bulk voltage
14.55 V
10
Abs voltage
14.35 V
11
Float voltage
13.30 V
12
Forced to float voltage
13.25 V
13
Gel voltage setting
55
mV
14
Diode compensation setting
60
mV
15
DC high alarm on
15.00 V
16
DC high alarm low
14.50 V
17
DC low alarm on
10.00 V
18
DC l ow alarm off
11.00 V
19
Alarm delay time
30
sec.
20
Reset data
WWYY
21
Battery identification no
00
• Temperature variation
5.0 mV/
°
C per cell
• Reference voltage 25
°
C
• Battery charging is not allowed
above +50
°
C and under -20
°
C
• 24 Volt 60 mV/
°
C
5.0 mV/
°
C
Uref 25
°
C
forced floatgel/wet battery
diode compensation
standard IUoUo characteristic
IUoUo char. increased with 0.6V
IUoUo char. high float level
IUoUo char. high float, increased with 0.6
IU char. low float level
IU char. low float, increased with 0.6V
IU char. high float level
IU char. high float, increased with 0.6 V
TEMPERATURE COMPENSATED CHARGING
charging voltage in V
15.0
14.5
14.0
13.5
13.0
12.5
12.0
-30
-20
-10
0
10
20
30
40
50
60
battery temperature in
°
C
float
absorption
25
°
C reference
temperature
MAX. BULK/ABS TIME
BULK TIME
TOTAL CHARGE TIME CYCLE
ABS TIME
FLOAT TIME
NEW CYCLE
min. bulk time
min. abs time
return to bulk time
MAX. OUTPUT VERSUS INPUT VOLTAGE
current in
Amps
input voltage
50
80
100
120
140
160
180
200
220
240
260
25
°
C reference
temperature
25
°
C reference
temperature
0
44
50
output current in Amps
Tamb= 25
°
C
charging voltage in V
CHARGING CHARACTERISTICS