CombiMaster 230V Series
– User and Installation Manual
17
5.2.1
Monitoring
A display, like the SmartRemote, Touch 5 (CZone) or EasyView 5 (MasterBus), can be used to monitor the CombiMaster. See
applicable user manuals for details. The following table lists the parameters as shown in MasterAdjust.
Menu
Description
Default
Adjustable range
General
Device state
The operation mode: Standby, Charging, Inverting, Supporting, Alarm
(read only)
AC IN Limit
Fuse setting of the AC input
30A
0-30A
Inverter button
Button to switch off/on the inverter
On
On, Off
Charger button
Button to switch off/on the charger
On
On, Off
DC IN/OUT
Charger state
Charger state: Off, Bulk, Absorption, Float
(read only)
Voltage
Battery voltage
(read only)
Current
Battery current (minus is discharging)
(read only)
Temperature
Battery temperature (if not connected: ---)
(read only)
AC IN
Input Voltage
AC input voltage
(read only)
Input Current
AC input current
(read only)
Input Frequency
AC input frequency
(read only)
AC OUT
Output Voltage
AC output voltage
(read only)
Output Power
AC output power
(read only)
Output Frequency AC output frequency
(read only)
Installer
Dry contact
Status alarm contact
(read only)
5.2.2
Alarms
The following table lists the parameters as shown in MasterAdjust.
Menu
Description
Temperature high Internal temperature of the CombiMaster is too high.
Fan error
An error has been detected in the fan.
DC high voltage
Battery voltage is too high.
DC low voltage
Battery voltage is too low.
Overload
The loads exceed the nominal inverter power
Device error
Internal CombiMaster error.
AC IN error
AC input voltage or frequency out of range
5.2.3
History
The following table lists the parameters as shown in MasterAdjust.
Menu
Description
Inverter runtime
Inverter mode operation hours
Charger runtime Charger mode operation hours
5.2.4
Configuration Settings
The configuration can be done in MasterAdjust, from a laptop or notebook connected to the CombiMaster via a Mastervolt
USB Interface. See applicable user manuals for details. The following table lists the parameters as shown in MasterAdjust.
Notes: -
DIP switch settings overrule MasterBus settings. If DIP switches are not in their default setting, the corresponding
MasterBus setting is grayed out.
-
To be able to make changes to the configuration via MasterBus, DIP switch 1 must be in the
ON
position.
Value
Meaning
Default
Adjustable Range
Device
Language
Menu language of this device
English
English, Nederlands
Name
Name of this device. This name will be recognized by all
devices connected to the MasterBus network
CombiMaster
0-12 chars
Device type
The CombiMaster model
(read only)