background image

 2   

 

Digital AC 1x6A 

– User and installation manual 

  

 

1.  GENERAL INFORMATION 

1.1 

Use of this manual 

This  manual  serves  as  a  guideline  for  the  safe  and 
effective operation of the Digital AC 1x6A. Read the 
entire manual before using the Digital AC 1x6A. Keep 
this manual in a secure place! 

1.2 

Liability  

Mastervolt can accept no liability for: 

 

Consequential damage resulting from the use of 
the Digital AC 1x6A. 

 

Possible  errors  in  the  included  manual  and  the 
consequences of these.  

 

Use  that  is  inconsistent  with  the  purpose  of  the 
product. 

1.3 

Warranty 

The  Mastervolt  product  warranty  covers  the  Digital 
AC  1x6A  for  the  first  two  years  after  the  purchase 
date, on the condition that the product is installed and 
used according to the instructions in this manual. 
Installation  or  use  that  do  not  comply  with  these  in-
structions may result in under performance, damage 
or failure of the product and may void this warranty. 
The  warranty  is  limited  to  the  cost  of  repair  and/or 
replacement of the product. Costs of labor or shipping 
are not covered by this warranty. 

 

CAUTION! 

Never remove the identification label.  
This will void the warranty. 

1.4 

Disclaimer 

Our  products  are  subject  to  continual  development 
and  improvement.  Therefore,  additions  or  modifica-
tions  to  the  products  may  cause  changes  to  the 
technical data and functional specifications. No rights 
can  be  derived  from  this  document.  Please  consult 
our most current Terms & Conditions of Sale. 

1.5 

Correct disposal of this product 

This  product  is  designed  and  manu-
factured with high quality materials and 
components,  which  can  be  recycled 
and reused. Please be informed about 
the local separate collection system for 

electrical  and  electronic  products.  Please  act 
according  to  your  local  rules  and  do  not  dispose  of 
your old products with your normal household waste. 
The  correct  disposal  of  your  old  product  will  help 
prevent  potential  negative  consequences  to  the 
environment and human health. 

 

2.  OPERATION 

The Digital AC 1x6A operation is entirely MasterBus based. For information about MasterBus and the MasterBus 
event structure, see www.mastervolt.com. The following table shows the relay functions. 

Monitoring 

Description 

Factory 
settings 

Range 

State 

Relay can be switched On (activate) or 
Standby 

Standby 

Standby/ Activate 

Control 

Change the state of the relay 

Standby 

Activate/ Standby  

Configuration General 

 

 

 

Language 

Set the MasterBus Digital AC menu language   English 

See specifications 

Device name 

Any name you wish with 12 characters max 

AC Relay 

1-12 characters 

Events locked 

Check box for installers to lock event 
configuration. Only operable by installers. 

Unchecked 

Unchecked/ 
Checked 

Shock resistance 
(Installer menu) 

For applications that experience large shocks 
and/or vibration on a regular basis (heavy 
duty/racing/etc). 
Turn on* will make the relay more 'sticky' and 
thus more resilient against shocks/vibrations. 

Off 

On/Off 

Configuration Timing 

 

 

 

Min. runtime 

Check box to enable the function 

Minimum 

runtime

 for switching the relay. 

Unchecked 

Unchecked/ 
Checked 

Min. runtime 

Minimum runtime setting 

15 minutes 

1-65535 minutes 

Max. runtime 

Check box to enable the function 

Maximum 

runtime

 for relay switching the relay. 

Unchecked 

Unchecked/ 
Checked 

Max. runtime 

Maximum runtime setting 

480 minutes 

1-65535 minutes  

*  This mode will increase the energy usage of the interface (by about 8mA continuously) as it will keep some power applied to 

the relay. This will keep the coil of the relay a little bit magnetized, which in turn will make it more 'sticky' to its current state. 