SPECIFICATIONS MASTERVOLT GEL BATTERIES – MVG SERIES
Model:
MVG 12/25
MVG 12/55
MVG 12/85
Part number:
64000250
64000550
64000850
Nominal voltage:
12V
12V
12V
Number of cells per battery:
6
6
6
Nominal capacity (C
20
@20ºC/68°F):
25Ah
55Ah
85Ah
Discharge current I
20
:
1.25A
2.75A
4.25A
Approximate weight:
9.6 kg / 21.2 Lbs
19 kg / 41.9 Lbs
32.6 kg / 71.9 Lbs
Internal resistance acc to (IEC 60896-21):
21.3mΩ
8.9mΩ
6.2mΩ
Short circuit current (IEC 60896-21):
583A
1403A
2018A
Cold Cranking Amps to DIN*:
110A
230A
270A
Cold Cranking Amps to SAE**:
175A
380A
450A
Model:
MVG 12/120
MVG 12/140
MVG 12/200
Part number:
64001200
64001400
64002000
Nominal voltage:
12V
12V
12V
Number of cells per battery:
6
6
6
Nominal capacity (C
20
@20ºC/68°F ):
120Ah
140Ah
200Ah
Discharge current I
20
:
6.00A
7.00A
10.00A
Approximate weight:
41 kg / 90.4 Lbs
49 kg / 108 Lbs
70 kg / 154.3 Lbs
Internal resistance (acc to IEC 60896-21):
5.2mΩ
4.1mΩ
3.5mΩ
Short circuit current (IEC 60896-21):
2475A
3132A
3606A
Cold Cranking Amps to DIN*:
450A
540A
630A
Cold Cranking Amps to SAE**:
760A
920A
1100A
*Cold Cranking Amps to DIN: 30 sec to min. 9.0V @ –18ºC/0ºF and 150 sec to min. 6.0V @ –18ºC/0ºF
**Cold Cranking Amps to SAE: 30 sec to min. 7.2V @ –18ºC/0ºF and 90 sec to min. 6.0V @ –18ºC/0ºF
Charger settings
Charge voltage settings for three step battery chargers (12V battery charger)
Float:
13.80V @ 25ºC / 77ºF
Absorption:
14.25V @ 25ºC / 77ºF (max 5 hrs)
Temperature compensation:
–30mV/ºC or –17mV/ºF
General
Operating temperature:
–20 to 45ºC / –4 to 113ºF;
Nominal operating temperature:
10 to 30ºC / 50 to 86ºF, recommended at 20ºC/ 68ºF
Storage temperature:
–40°C to 55°C / –40°C to 131ºF
Material of the battery container: Polypropylene (PP)
© Mastervolt BV, Snijdersbergweg 93, 1105 AN Amsterdam, Netherlands
Tel: + 31-20-3422100 Fax: + 31-20-6971006 Email: [email protected]
Mastervolt cannot be held liable for possible errors in the manual and the consequences of these.
Mastervolt kan niet aansprakelijk worden gesteld voor eventuele fouten in de handleiding en de gevolgen daarvan.
Mastervolt kann nicht haftbar gemacht werden für eventuelle Fehler in der Anleitung und die daraus entstehenden Folgen.
Mastervolt décline toute responsabilité dans les cas suivants éventuelles erreurs dans le manuel et leurs conséquences.
En ningún caso Mastervolt asumirá responsabilidad alguna derivada de eventuales errores en el manual de instrucciones y sus posibles consecuencias.
La Mastervolt declina ogni responsabilità per eventuali errori o omissioni nelle istruzioni per l'uso e le conseguenze che ne derivano.