16
4.7
CONNECTION
4.7.1
General
WARNING
Let installation work be done by a licensed
electrician.
All electrical systems (AC and DC) must be
disconnected from any power source during
the entire installation!
CAUTION!
Short circuiting or reversing polarity may lead
to serious damage to the batteries, the
ChargeMaster Plus, the cabling and/or the
terminal connections. Fuses between the
batteries and the ChargeMaster Plus cannot
prevent damage caused by reversed polarity.
The damage as a result of reverse polarity is
detectable by the service department and is
not covered by the warranty.
CAUTION!
Too-thin cables and/or loose connections can
cause dangerous overheating of the cables
and/or
terminals.
Therefore
tighten
all
connections well, in order to limit transition
resistance as far as possible. Use cables of
the correct size.
NOTE:
If the battery temperature remains within 15-
25°C, connection of the battery temperature
sensor is optional.
NOTE:
The ChargeMaster Plus is only feasible for the
connection of MasterBus compatible remote
control panels.