18
240V
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02
for utility charger.
30A (default)
Setting range is 2A, then from
10A to 100A. Increment of
each click is 10A.
12
Setting voltage point back
to utility source when
selecting “SBU” (SBU
priority) in program 01.
Available options for 24V model:
23V (default)
Setting range is from 22V to
25.5V. Increment of each click
is 1V.
Available options for 48V model:
46V (default)
Setting range is from 44V to
51V. Increment of each click is
1V.
13
Setting voltage point back
to battery mode when
selecting “SBU” (SBU
priority) in program 01.
Available options for 24V model: Setting range is FUL and from
24V to 29V. Increment of each click is 1V.
Battery fully charged
27V (default)
Available options for 48V model: Setting range is FUL and from
48V to 58V. Increment of each click is 1V.
Battery fully charged
54V (default)