background image

-4-

AIR SUPPLY AND CONNECTION

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as
tool may explode, possibly causing injury or death.

Do  not  use  supply  sources  which  can  potentially  exceed  200  P.S.I.G. as  tool  may
burst, possibly causing injury.

The connector on the tool must not hold pressure when air supply is disconnected.   If a
wrong fitting is used, the tool can remain charged with air after disconnecting and thus will
be able to drive a fastener even after the air line is disconnected possibly causing injury.

Do not pull trigger or depress contact arm while connected to the air supply as the tool may
cycle, possibly causing injury.

Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool;
3.) When clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work
area, as accidental actuation may occur, possibly causing injury.

LOADING TOOL

When loading tool: 1.) Never place a hand or any other part of the body in fastener
discharge area of tool; 2.) Never point tool at anyone; 3.) Do not pull the trigger or depress
the trip as accidental actuation may occur, possibly causing injury.

OPERATION

Always handle the tool with care: 1.) Never engage in horseplay; 2.) Never pull the trigger
unless nose is directed toward the work; 3.) Keep others a safe distance from the tool while
tool is in operation as accidental actuation may occur, possibly causing injury.

The operator must not hold the trigger pulled on contact arm tools except during fastening
operation as serious injury could result if the trip accidentally contacted someone or
something, causing the tool to cycle.

Keep hands and body away from the discharge area of the tool. A contact arm tool may
bounce from the recoil of driving a fastener and an unwanted second fastener may be
driven possibly causing injury.

Check operation of the contact arm mechanism frequently. Do not use the tool if the arm is
not working correctly as accidental driving of a fastener may result. Do not interfere with
the proper operation of the contact arm mechanism.

Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as
this may cause deflection of fasteners which could cause injury.

Do not drive fasteners close to the edge of the work piece as the wood may split, allowing
the fastener to be deflected possibly causing injury.

Do not point the tool toward yourself or anyone whether it contains fasteners or not.

Always ensure that the workpiece contact is fully positioned above the workpiece.
Positioning the workpiece contact on ly partially above the workpiece could cause the
fastener to miss the workpiece completely and result in serious personal injury.

MAINTAINING THE TOOL

When working on tools note the warnings in this manual and use extra care when
evaluating problem tools.

Содержание 208-5008

Страница 1: ...ALL OPERATORS SHOULD STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE IF YOU HAVE ANY QUESTIONS CONTACT YOUR...

Страница 2: ...foregoing this limited warranty does not cover any damage that has resulted from abuse or misuse of the Merchandise This warranty 1 excludes expendable parts including but not limited to blades brushe...

Страница 3: ...d repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury When servicing a tool use only identical replacement parts Use of unauthorized parts may cre...

Страница 4: ...stance from the tool while tool is in operation as accidental actuation may occur possibly causing injury The operator must not hold the trigger pulled on contact arm tools except during fastening ope...

Страница 5: ...rrect operating pressure for the tool FILTER Dirt and water in the air supply are major causes of wear in pneumatic tools A filter will help to get the best performance and minimum wear from the tool...

Страница 6: ...elps reduce work fatigue TOOL FREE DRIVE DEPTH ADJUST The tool free depth adjust lets the operator select precise driving depth of the fastener TOOL FREE JAM RELEASE A tool free jam release is provide...

Страница 7: ...ontrol of the fastener drive depth from flush with the work surface to shallow or deep countersink First set the air pressure for consistent drive in the specific work Then use the depth adjustment to...

Страница 8: ...ver point the tool at anyone else Never engage in horseplay Never pull the trigger unless nose is directed at the work Always handle the tool with care Do not pull the trigger or depress the trip mech...

Страница 9: ...FASTENER PLACEMENT To operate the tool in this manner first position the contact trip on the work surface WITHOUT PULLING THE TRIGGER Depress the contact trip until the nose touches the work surface a...

Страница 10: ...MUST NOT CYCLE Release the trigger The trigger must return to the trigger stop on the frame C Pull the trigger and press the contact trip against the work surface THE TOOL MUST NOT CYCLE D With finger...

Страница 11: ...PROCEDURE FOR SEALS When repairing a tool make sure the internal parts are clean and lubricated Use a small amount of oil on all moving surfaces and pivots After reassembly add a few drops of oil thr...

Страница 12: ...e Air pressure too low Check air supply equipment Skipping fasteners intermittent feed Worn bumper Replace bumper Tar dirt in driver channel Disassemble and clean nose and driver Air restriction inade...

Отзывы: