background image

O

PERATION

I

NSTRUCTIONS

A

SSEMBLY

I

NSTRUCTIONS

1) 

Remove the vacuum and hoses

packed inside the carton.

2) 

Unlatch the holdown clamps, lift off

motor head and carefully set aside.

3)

Remove the tools from inside the

vacuum tank.

4)

Install the strainer sack over the inlet

nozzle on the inside of the vacuum tank
and tighten draw string.

5)

Replace the motor head and engage

the holdown clamps.

6)

Ensure that the front gate valve on

the tank is completely closed (Plunger
should be in the down position).

7)

Ensure that the rear gate valve on

the tank is open half way. This is the
optiumum setting and will regulate the
discharge rate of the tank.

Note:

If the discharge rate exceeds the

intake rate, the pump will continuously
cycle ON and OFF and shorten the life of
the pump.

8)

Connect the 15 foot vacuum hose to

the front inlet of the vacuum tank.

9)

Connect on end of the 50 foot drain

hose to the rear gate valve and place
the other end into a suitable drain.

10)

Prime pump by filling the bottom

of the recovery tank with minimum of
3 inches of water to cover the injection
holes located at the bottom of the
pump.

11)

Replace motor head on the vacuum

tank and secure with the holdown
clamps.

M

AINTENANCE

I

NSTRUCTIONS

Vacuum Tank Inlet

15 Ft Vacuum Hose

5 Ft Metal Wand

Front Gate Valve

Line Cord w/GFI

14” Squeegee Tool

Rear Gate Valve

25 Ft

Discharge

Hose

12” Gulper Tool

Exercise caution when

handling the motor head.

Dropping the motor head

may cause permanent

damage to internal 

C

AUTION

:

Note

: For picking up deep water drop free end of the vacuum hose into water. When removing water

from a floor select the wand and squeegee or gulper tool. 

(See Page 7 for installation.)

1)

Plug the motor head’s power cord into

a standard 120V outlet, and plump’s
power cord into the convenience outlet in
the motor head.

2)

Turn ON the main switch located on the

motor head and the Pump-Out vacuum is
now operational.

Note:

When first turned 

ON

only the vacu-

um motor will be activated. When water
level in the tank reaches required height,
the pump’s float switch will be activated
and begin pumping.

The pump will shut 

OFF

when water level

lowers to a point that deactivates the float
switch.

The float switch is set at the factory to ensure proper operation and so that the

pump will maintain it’s required priming. Changing this setting could result in seri-

ous damage to the pump and void any warranty.

C

AUTION

:

1)

Drain the vacuum tank by opening the

front drain valve and tipping the vacuum
forward. 

2)

Close the gate valve and rinse the inside

of the tank with fresh water.

3)

Repeat step one.

4)

Empty the pump by removing the motor

head assembly, turn ON the motor head
and activate the pump by lifting the pump
float up by hand.

CAUTION

DO NOT

run in the mode for more 

than 20 seconds.

P

AGE

5

Содержание P42010SMP

Страница 1: ...vacuum is protectively packed to pre vent damage in shipment We recom mend that upon delivery unpack the vacu um and inspect it for any possible dam age Only a visual examination will reveal damage that may have occurred If damage is discovered immediately noti fy the transportation company that deliv ered your vacuum As a shipper we are unable to report claims for concealed damage You must origin...

Страница 2: ...ith any openings blocked keep free of dust lint hair and anything that may reduce air flow 9 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 10 DO NOT pick up anything that is smoking or burning such as cigarettes matches or hot ashes 11 DO NOT use without wet adaptor 12 Turn OFF all the controls before unplugging 13 Use extra care when cleaning on stairs...

Страница 3: ...porary adaptor should be used only until a properly grounded outlet Fig A can be installed by a qualified electrician The green color rigid ear lug or the like extending from the adaptor must be con nected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw Fig C Improper connection of the equipment grounding con...

Страница 4: ... cigarettes des allumettes ou des cendres chaudes 11 Ne pas utiliser l appareil si le sac à poussière ou le filtre n est pas en place 12 Mettre toutes les commandes à la position ARRET avant dé debrancher l appareil 13 User de prudence lors du nettoy age des escaliers 14 Ne pas aspirer des liquides inflam mables ou combustibles comme de l essence et ne pas faire fonctionner dans des endroits où pe...

Страница 5: ... Cord w GFI 14 Squeegee Tool Rear Gate Valve 25 Ft Discharge Hose 12 Gulper Tool Exercise caution when handling the motor head Dropping the motor head may cause permanent damage to internal CAUTION Note For picking up deep water drop free end of the vacuum hose into water When removing water from a floor select the wand and squeegee or gulper tool See Page 7 for installation 1 Plug the motor head ...

Страница 6: ..._______________________ 1 Switch 1 324140 2 Purse Lock 1 365483 3 Convenience Outlet 1 312495 4 Strain Relief 1 434299 5 50 Ft Power Cord w GFI 1 313149 6 10 24 Hex Nut w Lkwhr 3 331201 7 10 24 X 3 4 Screw 1 337315 8 Dome Assembly 1 320137 9 Flat Gasket 2 378607 10 Motor Holdown 1 396559 11 Circle Gasket 2 306975 12 Yellow Wire Connector 2 350648 13 120 Volt 11 4 HP Motor 1 337757 14 Cover Assembl...

Страница 7: ...cer 2 306762 _________________________________ _________________________________ Ref Parts Description Qty Part No No _________________________________ 1 11 2 X 50 Ft Discharge Hose 1 344729 2 11 2 X 15 Ft Vacuum Hose 1 344699 3 16 Squeegee Tool 1 414158 4 12 Gulper Tool 1 335371 5 5 Ft Double Bend Wand 1 363480 _________________________________ TANK ASSEMBLY REPLACEMENT PARTS LIST TOOLS HOSES AND...

Страница 8: ...d reset 4 Carbon brushes worn 4 Replace carbon brushes 5 Debris in the fan housing 5 Remove vacuum motor and clean out debris from fan PROBLEM Water blowing from vacuum when running CAUSE SOLUTION 1 Float ball is filled with water or damaged 1 Empty ball or replace if damaged 2 Float valve gasket is worn 2 Replace gasket 3 Foamy liquid is being picked up 3 Add defoamer to tank 4 Vacuum tank full n...