MasterCraft 62-3510-0 Скачать руководство пользователя страница 5

Operation

5

Troubleshooting

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Motor will not  

No electrical power

Check fuse, circuit breaker, power cord and 

start or run

electrical outlet.

Low line voltage

If voltage wiring under recommended minimum, 

check size of wiring from main source. If OK, 

contact Electric Company or local Hydro authority.

Faulty automatic switch

Operate switch manually and replace if inoperative.

Float or float rod stuck 

Check to see float is not rubbing sump wall or float 

rod rubbing or stuck against sump cover.

Waterlogged float

Replace float if filled with water.

Motor overload tripped

If pump has been running and stops before sump 

is emptied, automatic overload may have tripped. 

Check inlet screen to be sure impeller is not 

jammed. If so, free impeller of obstruction.

Electrical malfunction

Check power cord, automatic switch and motor. 

Replace faulty parts as needed.

Motor runs but   Inlet clogged

Check inlet and clean if needed.

pump will not 

Discharge line plugged

Clear discharge line and check valve for 

pump

obstruction.

Low line voltage

Refer to Corrective Action on low line voltage in 

above section.

Pump airlocked

Drill a 1/8" (3.2mm) hole in discharge pipe just 

above pump body but below the check valve.

Broken impeller or shaft

Replace impeller or shaft as needed.

Pump starts and  Improper positioning of 

Lower float rod stop.

stops too often

float rod stop 
Faulty automatic switch

Replace automatic switch.

Pump is noisy 

Improper installation 

Refer to No. 5  in Installation Instructions.

Noisy motor

Replace pump.

Pump will not 

Debris around float or

Remove debris from sump. Check to see float is 

stop running

float rod stuck

not rubbing sump wall or float rod rubbing or stuck 

against sump cover.

Faulty automatic switch

Replace switch.

Motor defective

Replace pump.

Unplug pump from power receptacle before working on pump. 

OPERATION

Do not touch sump pump, pump
motor, water, or discharge piping

when pump is connected to electrical power. Always
disconnect pump cord (power) before handling.

1.

Plug this unit into a 115V outlet, on an individ-
ual branch circuit, with a Class A, 15 amp
GFCI (Ground Fault Circuit Interrupter). 
Consult your local electrician for information
and availability.

2.

Fill sump pit with water, pump will start auto-
matically when lower rod stop actuates switch
lever arm. When upper rod stop actuates
switch lever arm, pump will stop.

NOTICE: 

Do not allow pump to run dry.

Before attempting to service,

always disconnect power

from unit.

3.

The motor is equipped with an automatic reset
thermal protector to protect unit from overheat-
ing. When motor has cooled sufficiently, switch
will reset automatically and restart motor.
Repeated tripping could be caused by low volt-
age, long extension cords, clogged impeller,
very low head or lift, etc. Cycling of protector
will cause eventual motor burnout.

Содержание 62-3510-0

Страница 1: ...Installation Operation Parts For further operating installation or maintenance assistance CONSUMER HOTLINE 1 877 455 5508 CTC842 8 27 09 MD OWNER S MANUAL Pedestal Sump Pump 62 3510 0 ...

Страница 2: ...carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period 62 3518 4 62 3522 2 62 3523 0 62 3558 8 62 3569 2 2 ...

Страница 3: ... cannot move around in sump 5 Secure discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property dam age 6 Check hoses for weak or worn condition before each use making certain all connections are secure 7 Inspect sump pump and system components monthly Keep free of debris and foreign objects Perform routine maintenance as required FIR...

Страница 4: ...nd wire system 6 Locate Float Rod Guide Key No 6 about 6 16cm below motor Clamp guide to column with screw provided Risk of flooding Be sure that guide is securely clamped so that float rod is vertical and can move up and down freely If float is angled or binds pump may not start allowing flooding to occur 7 Screw float onto threaded end of rod Threads on rod will cut threads into corrosion resist...

Страница 5: ...oper positioning of Lower float rod stop stops too often float rod stop Faulty automatic switch Replace automatic switch Pump is noisy Improper installation Refer to No 5 in Installation Instructions Noisy motor Replace pump Pump will not Debris around float or Remove debris from sump Check to see float is stop running float rod stuck not rubbing sump wall or float rod rubbing or stuck against sum...

Страница 6: ...Pump Body 1 S1 31B 3 Impeller 1 PS5 21P 4 Base Plate 1 PS4 17P 5 Float 1 FT0013 63 6 Float Rod Guide 1 RP0005249 7 Float Rod 1 RP005168S 8 Switch 1 9 Float Stop 2 RP0005248 Model 62 3510 0 If the motor fails replace the entire pump Select switch model number below Switch FP0020 Switch FP0018 7D ...

Страница 7: ...D GUIDE D UTILISATION Pompe d assèchement sur pied 62 3510 0 Installation fonctionnement pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien ASSISTANCE TÉLÉPHONIQUE 1 877 455 5508 ...

Страница 8: ... cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois Produit Période de garantie 62 3518 4 62 3522 2 62 3523 0 62 3558 8...

Страница 9: ...he Si à la suite de cela l interrup teur vient heurter le côté du puisard il se peut que l inter rupteur y adhère et empêche la mise en marche de la pompe Assurez vous de bien caler la pompe pour qu elle ne se déplace pas dans le puisard 5 Caler la canalisation de refoulement avant de démarrer la pompe Une canalisation non calée peut donner des coups de fouet qui risquent de provoquer des blessure...

Страница 10: ... Risques de débordement Le guide doit être correctement fixé pour que la tige du flotteur soit en position verticale et puisse monter et descendre librement Si le flotteur est incliné ou bloqué la pompe risque de ne pas démarrer ce qui peut provoquer un débordement 7 Viser le flotteur sur l extrémité filetée de la tige Le file tage de la tige taraudera un trou dans le flotteur résis tant à la corr...

Страница 11: ...position de Baisser l arrêt de la tige du flotteur démarre et l arrêt de la tige du s arrête trop flotteur souvent Interrupteur automatique Remplacer l interrupteur automatique défectueux La pompe Mauvaise installation Se reporter au N 5 des instructions d installation fait du bruit Moteur bruyant Remplacer la pompe La pompe Débris autour du flotteur Retirer les débris du puisard Vérifier si le fl...

Страница 12: ... 21P 4 Plaque du socle 1 PS4 17P 5 Flotteur 1 FT0013 63 6 Guide de la tige du flotteur 1 RP0005249 7 Tige du flotteur 1 RP005168S 8 Interrupteur 1 9 Butée du flotteur 2 RP0005248 Modèle 62 3510 0 Si le moteur tombe en panne remplacer la pompe Choisir le modèle d interrupteur en se reportant ci dessous Interrupteur FP0020 Interrupteur FP0018 7D ...

Отзывы: