MasterCraft 62-3510-0 Скачать руководство пользователя страница 3

Safety

3

DESCRIPTION

This Pedestal Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-
type power cord. Sleeve bearings on motor shaft never
need lubrication. Automatic reset thermal protection.
Pump water only with this pump.

NOTICE:

This unit is not designed as a waterfall, pond,

or fountain pump, or for applications involving salt
water or brine! Use with waterfalls, ponds, fountains,
salt water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

SPECIFICATIONS

Power supply required ........................115V, 60 HZ.
Horsepower ........................................................1/3
Motor duty .............................................Intermittent
Liquid Temp. Range ...............32°F to 70°F(0°-21°C)
Individual Branch Circuit 
Required GFCI Class A...............................15 Amps
Motor full load (maximum) .......................3.5 Amps
Discharge:.............................................1-1/2" FNPT

PERFORMANCE

GENERAL SAFETY

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from 
functioning normally. To prevent possible water
damage due to flooding, consult your retailer about
a secondary AC sump pump, a DC backup sump
pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for 
information about common sump pump problems
and remedies. For more information, call customer
service at 1-877-455-5508.
1.

Know the pump application, limitations, and
potential hazards.

Do not use in explosive

atmospheres. Pump water

only with this pump. Failure to follow this warn-
ing can result in personal injury and/or property
damage.

2.

Disconnect power before servicing.

3.

Release all pressure within system before ser-
vicing any component.

4.

Drain all water from system before servicing.

Risk of flooding. If a flexible
discharge hose is used, pump

may move when motor starts.

If it  moves far

enough so that switch hits side of sump, switch
may stick and prevent pump from starting.Make
sure pump is secured so it cannot move around
in sump.

5.

Secure discharge line before starting pump. An
unsecured discharge line will whip, possibly
causing personal injury and/or property dam-
age.

6.

Check hoses for weak or worn condition before
each use, making certain all connections are
secure.

7.

Inspect sump, pump and system components
monthly. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

FIRE HAZARD - Do not store

or rest objects on or near

motor or switch linkage. Keep all flammable
objects or liquids away from motor.

8.

Provide means of pressure relief for pumps
whose discharge line can be shut-off or
obstructed.

9.

Personal Safety:
a. Wear safety glasses at all times when work-

ing with pumps.

b. Keep work area clean, uncluttered and prop-

erly lighted – replace all unused tools and
equipment.

c. Keep visitors at a safe distance from work

area.

d. Make workshop child-proof – with padlocks,

master switches, and by removing starter
keys.

10. When wiring an electrically driven pump, fol-

low all electrical and safety codes, as well as
most recent National Electrical Code (NEC) and
Occupational Safety and Health Act (OSHA).

11. This equipment is only for use on 115 volt 

(single phase) and is equipped with an
approved 3-conductor cord and 3-prong,
grounding-type plug.

To reduce risk of electric

shock, be certain that it is

connected to properly grounded, grounding-
type receptacle.

Never connect green (or

green and yellow) wire in

cord to a live terminal!

Where a 2-prong wall receptacle is encoun-
tered, it must be replaced with properly
grounded 3-prong receptacle installed in accor-
dance with the National Electrical Code and
local codes and ordinances.

12.  All wiring should be performed by a qualified

electrician.

13. Make certain that power source conforms to

requirements of your equipment.

14. Protect electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking
cord. Replace or repair damaged or worn cords
immediately.

15. Do not touch an operating motor. Modern

motors can operate at high temperatures. Keep
the motor dry at all times.

16. Do not handle pump or pump motor with wet

hands or when standing on wet or damp sur-
face, or in water.

GPH (LPH) AT TOTAL FEET (M)

5 Ft.

10 Ft.

15 Ft.

20 Ft.

(1.52)

(3.05)

(4.57)

(6.09)

3000

2460

1620

0

(11 355L)

(9 312L)

(6 131L)

(0L)

Содержание 62-3510-0

Страница 1: ...Installation Operation Parts For further operating installation or maintenance assistance CONSUMER HOTLINE 1 877 455 5508 CTC842 8 27 09 MD OWNER S MANUAL Pedestal Sump Pump 62 3510 0 ...

Страница 2: ...carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period 62 3518 4 62 3522 2 62 3523 0 62 3558 8 62 3569 2 2 ...

Страница 3: ... cannot move around in sump 5 Secure discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property dam age 6 Check hoses for weak or worn condition before each use making certain all connections are secure 7 Inspect sump pump and system components monthly Keep free of debris and foreign objects Perform routine maintenance as required FIR...

Страница 4: ...nd wire system 6 Locate Float Rod Guide Key No 6 about 6 16cm below motor Clamp guide to column with screw provided Risk of flooding Be sure that guide is securely clamped so that float rod is vertical and can move up and down freely If float is angled or binds pump may not start allowing flooding to occur 7 Screw float onto threaded end of rod Threads on rod will cut threads into corrosion resist...

Страница 5: ...oper positioning of Lower float rod stop stops too often float rod stop Faulty automatic switch Replace automatic switch Pump is noisy Improper installation Refer to No 5 in Installation Instructions Noisy motor Replace pump Pump will not Debris around float or Remove debris from sump Check to see float is stop running float rod stuck not rubbing sump wall or float rod rubbing or stuck against sum...

Страница 6: ...Pump Body 1 S1 31B 3 Impeller 1 PS5 21P 4 Base Plate 1 PS4 17P 5 Float 1 FT0013 63 6 Float Rod Guide 1 RP0005249 7 Float Rod 1 RP005168S 8 Switch 1 9 Float Stop 2 RP0005248 Model 62 3510 0 If the motor fails replace the entire pump Select switch model number below Switch FP0020 Switch FP0018 7D ...

Страница 7: ...D GUIDE D UTILISATION Pompe d assèchement sur pied 62 3510 0 Installation fonctionnement pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien ASSISTANCE TÉLÉPHONIQUE 1 877 455 5508 ...

Страница 8: ... cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois Produit Période de garantie 62 3518 4 62 3522 2 62 3523 0 62 3558 8...

Страница 9: ...he Si à la suite de cela l interrup teur vient heurter le côté du puisard il se peut que l inter rupteur y adhère et empêche la mise en marche de la pompe Assurez vous de bien caler la pompe pour qu elle ne se déplace pas dans le puisard 5 Caler la canalisation de refoulement avant de démarrer la pompe Une canalisation non calée peut donner des coups de fouet qui risquent de provoquer des blessure...

Страница 10: ... Risques de débordement Le guide doit être correctement fixé pour que la tige du flotteur soit en position verticale et puisse monter et descendre librement Si le flotteur est incliné ou bloqué la pompe risque de ne pas démarrer ce qui peut provoquer un débordement 7 Viser le flotteur sur l extrémité filetée de la tige Le file tage de la tige taraudera un trou dans le flotteur résis tant à la corr...

Страница 11: ...position de Baisser l arrêt de la tige du flotteur démarre et l arrêt de la tige du s arrête trop flotteur souvent Interrupteur automatique Remplacer l interrupteur automatique défectueux La pompe Mauvaise installation Se reporter au N 5 des instructions d installation fait du bruit Moteur bruyant Remplacer la pompe La pompe Débris autour du flotteur Retirer les débris du puisard Vérifier si le fl...

Страница 12: ... 21P 4 Plaque du socle 1 PS4 17P 5 Flotteur 1 FT0013 63 6 Guide de la tige du flotteur 1 RP0005249 7 Tige du flotteur 1 RP005168S 8 Interrupteur 1 9 Butée du flotteur 2 RP0005248 Modèle 62 3510 0 Si le moteur tombe en panne remplacer la pompe Choisir le modèle d interrupteur en se reportant ci dessous Interrupteur FP0020 Interrupteur FP0018 7D ...