headline bars
continuation tabs
notes
warnings
headline bars
continuation tabs
notes
warnings
model no. 062-3408-6 | contact us 1-800-689-9928
4
QUICK ST
AR
T GUIDE
PLUGGING IN THE PUMP
Place the pump on a solid base in a
flooded area or any place that you
would like to remove water. Plug the
pump into a 115 V GFCI power
outlet.
2
OPERATING THE PUMP
Allow the pump to run and monitor its
progress.
Unplug the pump when it has removed
water down to approximately 1/2"
(12.7 mm).
3
CONNECTING GARDEN HOSE
Attach a garden hose with a 3/4" (19 mm)
garden hose thread (not included) to
the pump outlet.
1
1/2” (12.7 mm)
Anti-airlock
hole
1 1/2” (38.1 mm)
NOTE:
• Be sure the 3/4" (19 mm) garden hose thread connector has a rubber gasket to minimize water leaks.
• The larger the inside diameter and the shorter the length of hose, the less pressure that is lost (or the larger the
flow rate).
• Place upright on a solid base.
• The pump must be standing in at least 1 1/2" (38.1 mm) of water before you start it. The shaft seal is water
lubricated and may be damaged if the pump runs dry.
3/4" (19 mm) NH
thread
Submersible Utility Pump Function
CAUTION!
• Do not allow the plug to fall in water and do not stand in water while the pump is plugged in.
• Do not run the pump dry. Operating the pump without water will cause damage to the seals and will cause the pump to
fail, thereby voiding the pump’s warranty.
• The anti-airlock hole is for anti-airlock purposes only. Leakage of air or water is normal and necessary. DO NOT
REMOVE OR PLUG THE ANTI-AIRLOCK HOLE!