headline bars
continuation tabs
notes
warnings
15
ASSEMBL
Y INSTRUCTIONS
•
Attach the clear suction hose to the suction
strainer.
•
Then, place the strainer in at least 1" (2.5 cm) of
water at the lowest point to be pumped.
The following picture shows a typical installation. The suction lift of this unit can get up to 8' (2.4 m).
Be sure to use the included, specially designed built-in check valve suction strainer.
NON-SUBMERSIBLE TRANSFER PUMP INSTALLATION
CAUTION!
• Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the
pump and allow time for it to cool after periods of extended use.
WARNING!
• Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump
with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
• Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface or in water
while the pump is plugged in.
NOTE:
• Make sure the connection is airtight. An air leak can cause the pump to run dry.
• Always ensure the washer in the hose bib is not damaged. An airtight seal is necessary for this pump to operate.
Priming plug
Suction hose
Suction strainer
1" (2.5 cm)