SAFETY

SAFETY

WARNING

•  This pump must be monitored frequently (at least once a month, possibly more frequently if 

used in water that is full of debris). If the pump becomes clogged with debris (leaves, sticks, 
mud, etc.), excess pressure could cause the motor seal to weaken, and water could come in 
contact with the electric motor. Pump must not be used when connected to power outlet. 
NEVER STAND IN WATER WITH A RUNNING PUMP!

•  Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
•  Do not operate products in explosive atmospheres, such as in the presence of flammable 

liquids, gases or dust. Products create sparks which may ignite the dust or fumes.

•  Keep children and bystanders away while operating a product. Distractions can cause you to 

lose control of the situation.

•  This product is supplied with integral 18V lithium-ion batteries. Pump must be recharged only 

with the charger supplied with the pump.

•  When charging the pump, protect the power cord from being walked on or pinched particularly 

at plugs, convenience receptacles, and the point where they exit from the product.

•  Unplug this product and disconnect the battery when not in use.
•  Do not overreach. Keep proper footing and balance at all times. Proper footing and balance 

enable better control of the product in unexpected situations.

•  Prevent unintentional starting. Ensure the switch is in the off position before connecting to 

power source and/or battery pack, handle or carrying the tool. Carrying pump with your finger 
on the switch or energizing pumps that have the switch on invites accidents.

•  To reduce the risk of electrocution, do not touch plug with wet hands.

PUMP USE AND CARE

•  Do not use product if switch does not turn it on or off. A product that cannot be controlled with 

the switch is dangerous and must be repaired.

•  Disconnect battery pack from power supply and from product before making any adjustments, 

changing accessories, or storing the product. Such preventive safety measures reduce the risk 
of starting the product accidentally.

•  Do not drain water while charging.
•  Drain water from the pump before servicing.

CAUTION:

The pump has been designed for use with water only. Do not use with acids, alkalines, 
solvents, flammable material, gasoline or petroleum products, bleaches, or industrial grade 

solutions. These products can cause physical injuries to the operator and irreversible damage 

to the pump.

Содержание 062-3406-0

Страница 1: ...model no 062 3406 0 Submersible UTILITY PUMP INSTRUCTION MANUAL IMPORTANT Please read this manual carefully before running this pump and save it for reference ...

Страница 2: ...model no 062 3406 0 contact us 1 800 689 9928 2 ...

Страница 3: ...Troubleshooting 13 Warranty 13 TABLE OF CONTENTS TABLE OF CONTENTS NOTE If any parts are missing or damaged or if you have any questions please call our toll free helpline at 1 800 689 9928 SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product ...

Страница 4: ...70 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS 5 1 5 m 10 3 m 15 4 5 m 20 6 m 1163 U S GPH 4402 L h 925 U S GPH 3502 L h 635 U S GPH 2404 L h 450 U S GPH 1703 L h PERFORMANCE For best performance the maximum recommended hose length is 100 30 m The pumping capacity or water flow rate of any pump depends on several factors The larger the inside diameter and the shorter the length of hose the l...

Страница 5: ...oduct Unplug this product and disconnect the battery when not in use Do not overreach Keep proper footing and balance at all times Proper footing and balance enable better control of the product in unexpected situations Prevent unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack handle or carrying the tool Carrying pump with your fi...

Страница 6: ...nt 1 800 689 9928 Do not attempt to change the battery Under abusive conditions liquid may be ejected from the battery avoid contact If contact accidentally occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation or burns ADDITIONAL SAFETY PRECAUTIONS 1 Know the pump applications limitations and potential hazards 2 Make cer...

Страница 7: ...UMP FROM THE POWER SUPPLY BEFORE INSPECTING 11 Wear safety glasses at all times when working with pumps 12 Follow all electrical and safety codes particularly the National Electrical Code NEC or the Canadian Electrical Code CEC and in the workplace the Occupational Safety and Health Act OSHA or the Canadian Centre for Occupational Health and Safety CCOHS 13 Protect the electrical cord from sharp o...

Страница 8: ...ot included garden hose or hose kit The pump should rest on a level solid base Do not suspend the pump by the discharge hose or power cord Keep the pump inlet screen clear Do not install pump directly on sand or dirt The pond the pump is being placed into must have an underlayment laid down to prevent the pump from being clogged with mud debris etc WARNING Always use handle to lift pump Never use ...

Страница 9: ...is pump is 1 in However by using adaptors larger fittings and hoses can be used which can increase flow rates INSTALLATION INSTRUCTIONS Attach a 3 4 1 9 cm standard garden hose A not included to the adaptor B included on the pump C INSTALLATION INSTRUCTIONS A B C ...

Страница 10: ...tachments or accessories not recommended can result in serious personal injury 5 When assembling parts making adjustments cleaning or not using them turn off the pump to prevent accidental start resulting in serious personal injury NOTE The pump has internal protection functions built in to it The LED A will flash indicating the error function Please refer to the LED function chart to determine th...

Страница 11: ...hile charging lights will flash then turn to solid one by one as the power level reaches 30 60 and 100 Overload Turn off the pump Inspect the impeller to ensure there is not an obstruction causing the issue Battery fault Turn off the pump and send the pump to store for service CHARGING 1 Set the ON OFF switch A to the OFF position 2 Unscrew the waterproof nut D and do not loosen the O ring C on th...

Страница 12: ... contact us 1 800 689 9928 12 KEY PARTS DIAGRAM PARTS LIST KEY PARTS DIAGRAM No Description 1 Handle 2 Power indicator light 3 ON OFF switch 4 Pump outlet 5 Pump base 6 Charging port 7 Rope hole 8 Adaptor 1 2 3 4 5 6 7 8 ...

Страница 13: ...1 Battery out of power 2 Thermal overload 3 Corroded plug 4 Motor failed 1 Screen blocked 2 Hose kinked bent sharply or coiled 3 Airlock 4 Hose diameter too small 5 Hose length too long 6 Impeller loose on shaft 7 Impeller broken Pump does not start or run Pump cannot pump water out 1 Recharge the battery 2 Unplug the pump for 30 minutes then plug in 3 Clean plug prongs 4 Call service number on pa...