Continuity Test
Connect the black test lead to the "COM" jack and the red test
lead to the "VΩHz " jack ( Note: The polarity of the red lead is
positive " + " ).
Set the range switch to " " position.
Press "FUNC" button to make the display show " ".
Connect the test leads to the circuit to be measured.
If the circuit resistance is lower than about 50 Ω, the built-in
buzzer will sound.
Before performing in-circuit continuity test, make sure that the
circuit under test has all power removed and all capacitors are
fully discharged.
1.
2.
3.
4.
5.
Measuring Capacitance
Connect the black test lead to the "COM" jack and the red test
lead to the "VΩHz " jack.
Set the range switch to " " position.
Discharge the capacitor to be measured, and then connect the
test leads to the capacitor.
Wait until the reading is stable, then read the reading.
1.
2.
3.
4.