background image

 

 
 
 

GB

 IMPORTANT!!!  Carefully read  this service manual before 

you start to use, repair or clean the heater. Improper use of the 
appliance may cause serious injuries, burns, electric shock or fire.  
 

1.

 

Safety instructions. 

The appliance has been designed for heating closed areas such as e.g. 
warehouses, shops and houses It complies with  the Directive  No. EN  
73/23/EEC and 89/336/EEC (amended by 91/263/EEC, 92/31/EEC) as 
well as 93/68/EEC including the harmonised standards No. EN 60335-1 
and EN 60335-2. 

WARNING! Do not place the heater directly under the wall outlet. 
Do not touch internal components of the heater. 

This  appliance  is  not  intended  for  use  by  persons  (including  children) 
with  reduced  physical,  sensory  or  mental  capabilities,  or  lack  of 
experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their  safety.

 

Children  should  be  supervised  to  ensure  that  they  do  not 

play with the appliance. 

-

Do not cover the heater when it is operating. The appliance 

may get overheated. 

Do not operate the appliance close to humid places such as water 
tanks, bathtubs, showers or swimming pools. Any contact with water 
may be the reason of short-circuit or electric shock. 

The heater should be kept at a safe distance from flammable 
materials. The minimum safety distance should not be inferior to 0.5 
m, otherwise you run the risk of starting the fire.  

Do not use the heater in dusty spaces or rooms where gasoline, 
solvents, paints or other volatile and inflammable materials are 
stored  in order to avoid the risk of explosion. 

The heater should not be used close to the curtains or other textiles 
in order to avoid the risk of fire. 

Be particularly cautious when using the heater in the rooms 
frequented by children or animals.  

The heater should be supplied from a source meeting the 
requirements specified on the rating plate. 

Use only a feeder cable including the earth lead in order to avoid 
electric shock in emergency situations. 

Do not unplug the heater by pulling the wire out of the wall socket. 
The appliance should cool down through the ventilation effect. 

Unplug the heater when not used in order to avoid accidental 
damages. 

Before you dismantle the casing check if the feeder cable has been 
pulled out of the wall socket. Internal components may be live.   

2.

 

Unpacking and transport. 

Open the package and take the heater out including all the safety 
locks installed for the period of transport.  

Should the appliance seem damaged, notify immediately the seller 
of the same. 

Transport the heater using the lifting eyes No. 1 shown in Figs. 1, 2 
and , page 2. 

The heater should be transported in original package including the 
safety locks. 

3.

 

Description of individual components. 

See Figs. 1-2, Page. 2.

 

1) Lifting eye   

 8)   Back protective grid. 

2) Thermostat  

 9)   Power supply cable.    

3) Front protective grid 

10)  Base foot. 

4) Heating element 

11)  Fan.  

5) Casing 

 

12)  Motor . 

6) Switch 

 

7) Cable penetration.  
 
4.

 

Switching on. 

WARNING !!!: Carefully read  this service manual before you start 
to use the heater. The instructions contained herein will allow you 
to use the appliance in a safe manner.   

 

Make sure the power supply cable has not been damaged. If the 
supply cord is damaged, it must be replaced by the manufacturer, its 
service agent or similarly qualified persons in order to avoid a hazard.  
Moreover, check if the technical parameters of power supply source 
comply with the requirements specified on the rating plate. 
Place the appliance in its upright position. Make sure the switch is in 
its "0" position shown in Fig. 3. Connect the heater to the power 
supply source. Turn the switch and leave it for 5 seconds in the 
positions as follows:  

Fan only: Fig. 4;    

1

st

 degree of heating: Fig. 5, and     

2

nd

 degree of heating: Fig. 6.     

5.

 

Switching off. 

Turn the switch to its "0" position. Once the heating is off, leave the 
fan operating for 3 minutes.   

6.

 

Temperature control. 

The temperature in the room may be set by means of the control knob 
(Fig. 7, page 2). Once the pre-set temperature is produced, the  
thermostat will automatically  switch  the  heating elements off  while 
the fan will continue to operate thus protecting the appliance from 
overheating. If the temperature falls down beyond the pre-set value, 
the system will switch the heating elements on again.    

7.

 

Thermal circuit breaker. 

The appliance has been equipped with an integrated thermal circuit 
breaker ensuring high safety level. The breaker will automatically 
switch the power supply off once a limit temperature is exceeded.  
Should it happen, let the appliance cool down and only then, look for 
the reason of the problem. Next push the "RESET" button (Fig. 7) 
with a pointed tip in order to unlock the thermal circuit breaker. If the 
heater does not operate, contact the seller or approved service centre.   

8.

 

Out-of-season storage.   

Should the  appliance remain idle for  a  long  period  of  time,  clean 
it before shoving by blowing the inside with compressed air. The 
heater should be kept in a dry and clean place. Before you start using 
it again make sure the power supply cable  has not been damaged. In 
the case of any doubts contact the seller or approved service centre.   

9.

 

Functional inspection. 

The appliance should be checked at least once a year by competent 
service personnel approved by the manufacturer. Any inspections or 
repairs should be conducted by competent personnel only.

 

10. 

TROUBLESHOOTING

 

PROBLEM

 

REASON

 

SOLUTION

 

 

The motor operates while the appliance does 
not heat.    
 

Thermal circuit breaker is active. 
Thermostat has been damaged. 
Relay has been damaged. 
 Heating element has been damaged. 

Let the heater cool down and push the "RESET" button . 
Replace the thermostat. 
Replace the relay. 
Replace the heating element. 

The motor does not operate while the heating 
elements are hot. 

Motor has been damaged. 
Fan has been stopped.  
 Switch has been damaged. 

Replace the motor. 
Unlock / clean the fan. 
Replace the switch. 

The whole appliance does not operate. 

Electric circuit open. 
Switch has been damaged. 

Check power supply connection. 
Replace the switch. 

Reduced air flow. 

Foul air duct. 
Motor has been damaged. 

Open the air duct. 
Replace the motor. 

 
 

Содержание B 5 EPA R

Страница 1: ...B 5 EPA R GB Electric air heater Owner manual RU 4510 679V1 2010...

Страница 2: ...h position 2 kW Fan Switch position 3 kW 3 3 Switch position 4 kW 5 Max current cons A 22 Voltage V Hz 230 50 Air displacement m3 h 510 Temperature range 0 C 5 35 Weight kg 9 Dimensions l w h cm 36 25...

Страница 3: ...itching on WARNING Carefully read this service manual before you start to use the heater The instructions contained herein will allow you to use the appliance in a safe manner Make sure the power supp...

Страница 4: ...4 RU 1 73 23 89 336 91 263 92 31 93 68 EN 60335 1 EN 60335 2 30 5 1 0 5 2 1 1 2 2 3 1 2 2 1 8 2 9 3 10 4 11 5 12 6 7 4 0 3 5 4 5 6 5 0 3 6 8 2 7 RESET 7 8 9 10 RESET...

Страница 5: ...5 GB WIRING DIAGRAM RU W switch M motor WR temperature limiter WZ overheat sensor T thermostat PK relay L coil R1 R2 R3 heating elements Master B 5 EPA R...

Страница 6: ...ns the product is covered by the European Directive 2002 96 EC Please inform yourself about the local separate collection system for electrical and electronic products Please act according to your loc...

Страница 7: ...___________________________ ________________________________________________________________________ ________________________________________________________________________ __________________________...

Страница 8: ...8 DESA Italia SPA Via Tione 12 Pastrengo Verona VR Italy 37010 www desaitalia com DESA Poland Sp z o o ul Magazynowa 5a 62 023 G dki Poland www desapoland pl...

Отзывы: