1.

INTAKE GRILLE REMOVAL

(1) Open the intake grille.
(2) Open the intake grille and lift the intake grille upward until the hook

at the top of the intake grille is unhooked.

Fig. 54

2.

FRONT PANEL REMOVAL

(1) Remove the four tapping screws.
(2) Remove the front panel by lifting the bottom of the front panel

upward.

Fig. 55

3.

FRONT PANEL INSTALLATION

(1) Hook the top hole of the front panel to the hook of the base.
(2) Fasten the front panel with the screw.

Fig. 56

FRONT PANEL REMOVAL

 CAUTION

Install the front panel and intake grille securely. If in-
stallation is imperfect, the front panel or intake grille
may fall off and cause injury.

UNIT A1 and A2

1.

INTAKE GRILLE REMOVAL

(1) Place your fingers at both lower ends of the grille panel, and lift

forward; if the grille seems to catch partway through its movement,
continue lifting upward to remove.

(2) Pull past the intermediate catch and open the intake grille wide so

that it becomes horizontal.

Fig. 50

2.

UNLOCK THE INTAKE GRILLE

Hold the intake grille with one hand and pull the knobs on the right and
the left all the way to unlock the intake grille.

Fig. 51

(1) Remove the two screws.
(2) Unhook the tab at the center of the front panel.
(3) Remove the front panel by lifting it in the arrow direction.

Fig. 52

3.

FRONT PANEL INSTALLATION

(1) Engage the body tabs by pressing on the top of the unit at the three

points indicated by the arrows until the tabs make a sound.

(2) Engage the tab at the center of the front panel and fasten the front

panel with the two screws.

Fig. 53

Tapping screw

(Hook)

Open

Lift

Intake
grille

Lift

Lift

(Hook)

Open

Front
panel

(Top hook)

Front panel

(Top hole)

Intake grille

Be sure that the top hole of the front panel is attached securely to
the hook of the base.

Mounting shaft

Raise the horizontal intake grille to remove it.

Tab

Tab

Knob

Содержание 9369651014

Страница 1: ...erheating at connection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to...

Страница 2: ...0 F 35 C DB 110 F 43 3 C DB humidity about 80 or less Cooling Minimum 65 F 18 C DB 32 F 0 C DB STANDARD ACCESSORIES The following installation accessories are supplied Use them as required INDOOR UNIT...

Страница 3: ...at the wall hook bracket Wall hook bracket Tapping screw big Handle of screwdriver Tap Hook String Wall hook bracket Hook Counter weight Center notch 1 Cut a 3 2 16 80 mm diameter hole in the wall at...

Страница 4: ...ain hose through the wall hole hang the indoor unit on the hooks at the top and bottom of the wall hook bracket Fig 8 Connection pipe 1 4 6 35 mm dia Align the marks Connection pipe 3 8 9 52 mm dia or...

Страница 5: ...fere with the air flow 2 Install the outdoor unit in a place where it will be free from be ing dirty or getting wet by rain as much as possible 3 Install the unit when connection to the indoor unit is...

Страница 6: ...ere it is intended to be installed If the place is not strong enough a plank or girder should be used to make the place sufficiently strong so that the wall can support the weight Installation directl...

Страница 7: ...o 10 mm less 3 8 10 mm or over 3 15 16 100 mm dia hole 1 Rear piping 2 Right piping 3 Bottom piping Install the indoor unit piping in the direction of the wall hole and bind the drain hose and pipe to...

Страница 8: ...onnec tion cord as shown in Fig 23 beforehand Fig 23 Left piping Drain insulation Drain hose Vinyl tape Indoor unit drain hose Indoor unit Connection cord Pipe Connect the piping Drain hose INSTALLING...

Страница 9: ...INDOOR UNIT OUTDOOR UNIT Check if L is flared uniformly and is not cracked or scratched L dimension Thin pipe 6 35 mm dia 1 4 to 1 7 mm Thick pipe 12 7mm dia 1 9 to 2 2 mm 4 CONNECTION 1 Install the...

Страница 10: ...trip 3 8 10 mm Strandwire Screw with special washer Screw with special washer Round terminal Round terminal terminal board Round terminal Wire Wire WARNING 1 Before starting work check that power is n...

Страница 11: ...Cabinet D Knockout hole Edge cover Pipe mounting hole Power supply line Inter Unit line 3 Connect the piping and power supply cord from the mounting holes 4 Temporarily mount the conduit tubes on the...

Страница 12: ...ocess the end of the connection cords to the dimension shown in Fig 40 and bend the end of each wire as shown 5 Connect the end of the connection cord fully into the terminal board and fasten with the...

Страница 13: ...ve core OUTDOOR UNIT Cap OUTDOOR UNIT 3 way valve 2 way valve Service hose Gauge manifold Vacuum pump Connection pipe WARNING 1 The rated voltage of this product is 230 208 V A C 60 Hz 2 Before turnin...

Страница 14: ...ler so that rain water and wind cannot blow in 6 Fasten the drain hose to the outside wall etc UNIT B Installing the under covers 1 Installing under cover A Fig 42 1 Hook the two pipe bracket hooks to...

Страница 15: ...ovement continue lifting upward to remove 2 Pull past the intermediate catch and open the intake grille wide so that it becomes horizontal Fig 50 2 UNLOCK THE INTAKE GRILLE Hold the intake grille with...

Страница 16: ...here any gas leakage Do not operate the air conditioner in the test run mode for a long time For the operation method refer to the operating manual and per form operation check Error display Error con...