Symptom:

  Leak to Drain 

 

Possible Cause 

Solution 

No flow control installed in drain 
line. 

Install drain line flow control. 

Insufficient water pressure. 

Increase water pressure above 25 
psig (172kPa) minimum. 

Damaged valve disk or obstruction 
in valve disk. 

Inspect and if damaged, replace all 
valve disks or remove obstruction. 

 

Symptom:

  Loss of Water Pressure 

 

Possible Cause 

Solution 

Fouled resin bed due to iron 
accumulation. 

Clean control valve and mineral bed 
with cleaner. 

Slots in riser pipe or laterals are 
filled with resin fines. 

Inspect and clean distributor pipe slots 
as needed. 

 

Symptom:

  Salt in Water to Service After Regeneration 

 

Possible Cause 

Solution 

Injector is too small for system size.  Install correct injector 
Brine draw time excessively long 
due to low water pressure. 

Increase water pressure above 25 
psig (172 kPa) minimum. 

Restricted drain line. 

Remove drain line restriction. 

Insufficient rinse volume. 

Increase slow rinse time, fast rinse 
time, or both. 

Damaged valve disk. 

Replace all valve disks. 

Plugged injector and/or injector 
screen. 

Inspect and clean injector and/or 
injector screen. 

 

Содержание MP-MBA-15T

Страница 1: ...Installation and Operation Manual MP MBA 15T 30T using the 255 762 Logix Control Valve July 2006 MASTER Water Conditioning Corp www masterwater com...

Страница 2: ...ne Tank Brine Tubing Brine tank 7 Logix 255 762 Control Valve Electrical Connection Instructions on Logix 762 Electrical Connection 8 Filling Softener with Water Filling Softener with Water 9 Filling...

Страница 3: ...r to initiate regeneration The Logix Valve is constructed of non corrosive Noryl material and is rated at a maximum working water pressure of 100 psi This softener includes a manually operated bypass...

Страница 4: ...ar enough from walls and other obstructions to allow for servicing the unit 2 Place the water softener within reasonable access to a grounded 115V 60 HZ circuit and a legal drain line connection Logix...

Страница 5: ...s of the control valve are 3 4 copper or pvc and are located on the back of the valve body As you face the timer the inlet is on the left and the outlet is on the right Always follow local plumbing co...

Страница 6: ...Maximum drain line height is 6 feet above the control valve The drain line must be piped to an open air gap See Figure 3 Always follow local plumbing codes UNDER NO CIRCUMSTANCES SHOULD THERE BE A DIR...

Страница 7: ...or water meter if its public water supply Master Water Conditioner Brine tank Air Gap Drain Overflow fitting to floor drain gravity Treated water Untreated to outside 224 Shoemaker Rd Pottstown PA 19...

Страница 8: ...mps 3 Make sure the electrical service provides power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The br...

Страница 9: ...already installed at the factory 1 Remove plastic control valve cover by spreading sides while lifting 2 Plug transformer into back of timer following existing wires 3 Plug transformer into a properly...

Страница 10: ...L THE RESIN WILL BE FLUSHED TO DRAIN DURING START UP 2 When water is running steadily at the drain open the bypass valve s inlet and outlet to their maximum position 3 Simultaneously press the SET and...

Страница 11: ...ss the SET button The screen will show the Day of Week in blinking triangle 2 To change the Day of Week use the UP or DOWN arrows 3 Press the SET button Time of Regeneration Setting the factory defaul...

Страница 12: ...use the UP or DOWN arrows 3 Press the SET button Note The screen will now flash between flow rate and gallons remaining until next regeneration If water was tested by Master Water Conditioning follow...

Страница 13: ...11...

Страница 14: ...ual bypass valve Leak at riser pipe seal Insure that riser pipe is properly sealed at o ring seal Inspect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Ch...

Страница 15: ...o height of valve Damaged valve disk Replace all valve disks Partially restricted drain line Remove restriction Symptom Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control R...

Страница 16: ...ral bed with cleaner Slots in riser pipe or laterals are filled with resin fines Inspect and clean distributor pipe slots as needed Symptom Salt in Water to Service After Regeneration Possible Cause S...

Страница 17: ...15...

Страница 18: ...16...

Страница 19: ...17...

Страница 20: ...18...

Страница 21: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...

Отзывы: