background image

LEGACY STEREO SYSTEM

32

*Please refer to your stereo Owner’s Manual for specific operations.

Your Spa Stereo System includes a CD/FM stereo with two surface mounted
speakers. 
When adding chemicals, please be sure to leave your spa cover open for at least
15 minutes after adding chemicals to prevent off gas damage to speakers, pil-
lows and plastic parts.
The speaker compartment of your spa has a drain at the bottom of the spa
frame to prevent water from accumulating and sitting stagnant. Please note
that this drain runs down to the corner of the spa and will leak out should water
collect in these compartments. Please also note that should the drain become
blocked, water will not drain out, causing your marine grade speaker to become
completely submerged in water. Any damage caused by this is not warranted.

Note: If you are installing your spa indoors, always be aware that if you 
splash water into the speaker compartments of the spa, water will run down
through the speaker drain which drains below the spa in the corner where the
speakers are located. Please be aware of this as any damage is not covered by
the warranty. This could cause unwarranted damage.
Note: Do not place wet CDs into the stereo at anytime.

Note: AM channels will be very limited in reception and in most cases unavailable.

CAUTION –

Risk of Electric Shock. Do not leave compartment door open.

CAUTION – 

Risk of Electric Shock. Replace components only with identical 

components; and

Do not operate the Audio / Video controls while inside the spa.

WARNING –

Prevent Electrocution. Do not connect any auxiliary 

components (for example cable, additional speakers, headphones, additional
Audio / Video components, etc.) to the system.

NOTE: These units are not provided with an outdoor antennae; when provided,
it should be installed in accordance with article 810 of the National Electrical
Code, ANSI / NFPA 70.
NOTE: Do not service this product yourself as opening or removing covers may
expose you to dangerous voltage or other risk of injury. Refer all servicing to
qualified service personnel.
NOTE: When the power supply connections or or power supply cord(s) are 
damaged; if water is entering the Audio / Video compartment or any electrical
equipment area; if the protective shields or barriers are showing signs of 
deterioration; or if there are signs of other potential damage to the unit, 
turn off the unit and refer servicing to a qualified service personnel.
NOTE: This unit should be subjected to periodic routine maintenance 
(for example, once every 3 months) to make sure that the unit is 
operating correctly.

Warning:

Never remain in your spa longer than 15 minutes per session when 

the water temperature is above 98˚F. If you wish to spend more time in your spa,
whether enjoying music, or just lounging, be sure to keep the spa water at or
below body temperature (98.6˚F).

Master Spa Parts

Call Us Today: - (920)727 - 1700

Master Spa Parts - 1068 American Drive, Neenah, WI, 54956, USA

Содержание 2008 Legacy Whirlpool

Страница 1: ...2008 OWNER S MANUAL...

Страница 2: ...Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 3: ..._____________________________________ Address ____________________________________________________________________ City _____________________________________ State __________ Zip ______________ Date P...

Страница 4: ...e 19 Spa Water Maintenance Start Up 20 22 Water Maintenance Trouble Shooting Guide 23 Why Chemicals are Important in a Spa 24 Maintenance Recommendations 25 Winterizing Your Spa 26 Legacy Spa Specific...

Страница 5: ...permanent fastener Additional or replacement signs can be obtained from your dealer or direct from the factory INTRODUCTION It s time to relax You now have your very own portable spa by Master Spas In...

Страница 6: ...f in accordance with the National Electrical Code each metal surface is permanently connected by a minimum No 6 AWG 8 4mm solid copper conductor attached to the wire connector on the terminal box A gr...

Страница 7: ...sure or circulatory system problems should consult a physician before using the spa F Since excessive water temperatures have a high potential for causing fetal damage during early months of pregnancy...

Страница 8: ...d temperatures above 99 F Children should spend less time in water above body temperature than adults 8 WARNING The use of alcohol drugs or medication can greatly increase the risk of hyperthermia J T...

Страница 9: ...o components etc to the system These units are not provided with an outdoor antennae Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other haz...

Страница 10: ...ment 16 At least two lugs marked Bonding Lugs are provided on the external surface or on the inside of the supply terminal box or compartment To reduce the risk of electric shock connect the local com...

Страница 11: ...ATTEINTES DE MALADIES INFECTIEUSES NE DEVRAIENT PAS UTILISER UNE CUVE DE RELAXATION WARNING TO AVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE SPA OR HOT TUB AVERTISSEMENT POUR VITER DES BLESS...

Страница 12: ...DE RELAXATION CAUTION MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH MANUFACTURER S INSTRUCTION ATTENTION LA TENEUR DE L EAU EN MATI RES DISSOUTES DOIT TRE CONFORME AUX DIRECTIVES DU FABRICANT Hyperther...

Страница 13: ...d for maximum jet action The main pump is controlled by the Jets or Jets I button on the Topside Control Panel 3 SECONDARY PUMP This produces water flow through the other jet system in the spa if appl...

Страница 14: ...trical supply for your spa must include a 50 AMP switch or circuit breaker to open all non grounded supply conductors to comply with section 422 20 of the National Electrical Code The disconnect must...

Страница 15: ...e is not required between the G F C I and the system box GRN GRN GROUND RED HOT BLK HOT BLK HOT RED HOT RED HOT WHT NEUTRAL WHT WHT BLK HOT GRN GROUND TB1 IDF00007 mac 6 17 97 Actual wiring of GFCI wi...

Страница 16: ...red by the warranty This could cause unwarranted damage 3 Surface Pad Requirements When your new spa is filled with water and bathers it may weigh as much as several tons It is imperative that the bas...

Страница 17: ...ith proper planning no matter what room your spa goes in it will be your favorite room Work with your Master Spas dealer and contractor to insure all local building electrical and plumbing codes are m...

Страница 18: ...e to the nature of water flow and hydro therapy pumps please be advised that air locking of pumps may occur Master Spas has taken measures to reduce the possibility of this but it still may occur espe...

Страница 19: ...the lower the pH pH is not measured in parts per million but on a scale from 0 to 14 with 7 being the neutral In spas when ever possible a measurement between 7 2 and 7 8 is best Whenever possible it...

Страница 20: ...is a granule fast dissolving and pH neutral 2 Chlorine is an immediate sanitizer B Bromine 1 Two types of tablets a Hydrotech b Lonza 2 Bromine is a slow dissolve chemical and may take a few days to...

Страница 21: ...ock treat with 1 teaspoon of Dichlor per 500 gallons These are general recommendations for water quality maintenance that may vary by usage and or bather load Depending on bather load and frequency of...

Страница 22: ...ecessary to within the 7 2 and 7 8 range using the pH alkalinity increaser or decreaser 1 2oz at a time Wait 15 minutes retest and adjust if necessary The pump should be running on high speed during t...

Страница 23: ...the label directions 5 Use a small amount of defoamer only if necessary DAY TWO SKIP DAY THREE 1 Test and adjust total alkalinity if necessary to between 80 and 150 ppm using the pH alkalinity increa...

Страница 24: ...r superchlorinate following label directions A spa should be shocked at least once a week even if it is not used If using chlorine as the sanitizer the spa should be shocked whenever a free chlorine r...

Страница 25: ...ls lotions soap etc HOW TO FIX IT Shock water with non chlorine shock treatment Adjust pH if necessary Shock water with non chlorine shock treatment or adjust sanitizer levels Adjust pH level if neces...

Страница 26: ...ronment surrounding the spa is also a consideration Watch for pollen grass sand dirt lawn fertilizer dust storms insects dogs cats etc 5 Consider the human next In a heated spa the average adult sweat...

Страница 27: ...spa is one of the most important components of your spa It not only is essential for clean water but also for extending the life of the spa equipment Your filter element must be cleaned regularly once...

Страница 28: ...rom equipment area 4 Loosen all pump unions 5 Remove winterizing plug from the face of the pump s 6 Using your shop vac in a blowing mode insert the hose into the nozzle of each jet and blow the trapp...

Страница 29: ...Pumps Count INTREPID 94 x 94 x 36 240V 485 700 2 40 50 Amp 7 740 ENTERPRISE 84 x 84 x 36 240V 410 655 2 40 50 Amp 4 070 INSPIRE 84 x 84 x 36 240V 425 650 2 40 50 Amp 4 190 ENVISION 78 x 84 x 32 240V 3...

Страница 30: ...or lower the set temperature If the opposite direction is desired for a 1 pump unit release the pad and let the display revert to the current water temperature Press the pad to display the set tempera...

Страница 31: ...and will alternate with temperature when temperature is current Preset Filter Cycles The first filter cycle begins 6 minutes after the spa is energized The second filter cycle begins 12 hours later F...

Страница 32: ...activate regardless of spa status If the problem persists contact your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools If the problem...

Страница 33: ...alternating with spa temperature it may just be a temporary condition If flashing by itself spa is shut down A significant difference between temperature sensors has been detected This could indicate...

Страница 34: ...open CAUTION Risk of Electric Shock Replace components only with identical components and Do not operate the Audio Video controls while inside the spa WARNING Prevent Electrocution Do not connect any...

Страница 35: ...OPERATE 1 Press the Jets button on your control panel If you hear the pumps trying to operate A Pump may need to be primed See page 16 If you do not hear anything from the pump contact your local ser...

Страница 36: ...e spa should be heating Wait a reasonable amount of time approximately 1 hour to see if the water temperature is changing 6 Check to make sure that the pump is primed 7 Reset power to the spa at GFCI...

Страница 37: ...ng on model TO CLEAN JETS Place the jet s in a bucket fully immerse in white vinegar Let the jet s soak overnight and then rinse with water Reinstall the jet s It may also be necessary to clean the gr...

Страница 38: ...ONGED PERIODS DO NOT REPLACE COVER DIRECTLY ON SURFACE OF SPA PLACE 2 3 BLOCKS BETWEEN COVER AND SPA THIS ALLOWS FOR ADEQUATE VENTILATION OF COVER AND SPA NOTE The cover warranty is provided through t...

Страница 39: ...er Cartridge Test GFCI Soak Filter Cartridge in Solution Clean and Condition Spa Cover Miscellaneous Service Miscellaneous Service DATE DATE DATE DATE DATE DATE DATE Master Spa Parts Call Us Today 920...

Страница 40: ...38 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 41: ...SPA CARE AND MAINTENANCE RECORD 39 DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 42: ...SPA CARE AND MAINTENANCE RECORD 40 DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE DATE Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 43: ...Master Spa Parts Call Us Today 920 727 1700 Master Spa Parts 1068 American Drive Neenah WI 54956 USA...

Страница 44: ...hind every product we produce pursuant to those representations which are stated in our written limited warranty your dealer is an independent business person or company and not an employee or agent o...