![Master Pumps 5411074199029 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/master-pumps/5411074199029/5411074199029_original-instructions-manual_1737632026.webp)
SWITCHING ON AND OFF
1. Place the terminal box on a lever surface.
2. Lift the cover of the terminal box and insert the charged battery along the guide rail into the apparatus.
You should be able to hear the rechargeable battery lock into place.
To switch on: Press the ON/OFF switch to ‘I' position
To switch off: Press the ON/OFF switch briefly to ’O' position
TECHNICAL DATA
Type
Clean and slightly dirty water
Voltage
20V
Power
120W
Max. pump capacity
3000 L/h
Max. lift
7 m
Max. submerging depth
5 m
Max. grain size
2.5mm
Max. water temperature
35 °C
Type of protection / Insulation class
IPX8
Battery LITHIUM
LITHIUM
Battery capacity
2000 mAh
Charger
CHAR20V15FA
AC 220- 240V~ 50/ 60Hz
1.2A 20Vd.c 2000mA
Charging duration battery
1 h
Max working time
25min
Weight
3.17 kg
ATTENTION !
The sound power pressure may exceed 85 dB(A), in this case
individual hearing protection must be worn.
Weighted root mean square acceleration according to relevant standard. : < 2.5 m/s²
The declared vibration total value has been measured in accordance with a standard
test method and may be used for comparing one tool with another that the declared vibration total
value may also be used in a preliminary assessment of exposure.
A warning that the vibration emission during actual use of the power tool can differ
from the declared total value depending on the ways in which the tool is used and of the need to