NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2018 Pinnacle Climate Technologies, Inc.
Kerosene Forced Air Heater User’s Manual
11
WIRING DIAGRAM
MAINTENANCE
PUMP PRESSURE:
While heater is operating, turn adjusting screw
clockwise to increase, counter-clockwise to
decrease pressure (see Figure 11). Correct pump
pressure is as follows:
Model Number
Pump Pressure
MHP-135-KFA
5.5 PSI (0.38 BAR)
MHP-190-KFA
8.5 PSI (0.59 BAR)
MHP-215-KFA
9.0 PSI (0.62 BAR)
Tolerance ± 10%
NOZZLES:
Nozzles should be cleaned or replaced at
least once per heating season (see Figure 12).
Contaminated fuel could make this necessary
immediately. To clean dirt from nozzle, blow
compressed air through nozzle front. It may be
necessary to soak the nozzle in K-1 kerosene to
loosen any dirt particles.
Figure 11
Adjusting Screw
Pressure Valve
Figure 12
Nozzle
Nozzle Face
Burner Head
CAPACITOR
SPARKPLUG
BLUE
EARTH
GREEN
AC 120V 60Hz
POWER
PLUG
CN2
BLUE
BLUE
WHITE
BLACK
BLACK
(TEMP.CONTROL)
THERMOSTAT
BLACK
BLACK
SWITCH
POWER
PHOTO CELL
CD5
SENSOR
ROOM
CN3
CONTROL
LIMIT
5A/250VAC
ACN1
BLACK
FUSE
R-TH
MOTOR02
ACN2
WHIT
E
GREEN
EARTH
CONTROL PCB
RUN
TIMER
MOTOR01
CN1
IGNITOR
BLACK
BLUE
BLUE
MOTOR
PUMP
BLUE
BLACK
RED
EMPTY
FULL
CN4
LEVEL
SWITCH
CON4