background image

Page 6 

watches when working with a lead-

acid battery. A lead-acid battery can 

produce a short-circuit current high 

enough to weld a ring or the like to 

metal, causing a severe burn.

2.8 

Use the charger for charging only 6 

and 12V LEAD-ACID (STD, GEL or 

AGM) rechargeable batteries. It is not 

intended to supply power to a low 

voltage electrical system other than 

in a starter-motor application. Do 

not use battery charger for charging 

dry-cell batteries that are commonly 

used with home appliances. These 

batteries may burst and cause injury 

to persons and damage to property.

2.9 

NEVER charge a frozen battery.

3. PREPARING TO CHARGE

3.1 

If necessary to remove battery from 

vehicle to charge, always remove 

grounded terminal from battery first. 

Make sure all accessories in the vehi-

cle are off, so as not to cause an arc.

3.2 

Be sure area around battery is well 

ventilated while battery is being 

charged.

3.3 

Clean battery terminals. Be careful to 

keep corrosion from coming in con-

tact with eyes.

3.4 

Add distilled water in each cell until 

battery acid reaches level specified by 

battery manufacturer. Do not overfill. 

For a battery without removable cell 

caps, such as valve regulated lead 

acid batteries, carefully follow manu-

facturer’s recharging instructions.

3.5 

Study all battery manufacturer’s spe-

cific precautions while charging and 

recommended rates of charge.

3.6 

Determine voltage of battery by 

referring to car owner’s manual and 

make sure that output voltage selec-

tor switch is set at correct voltage. If 

charger has adjustable charge rate, 

charge battery initially at lowest rate.

4. CHARGER LOCATION

4.1 

Locate charger as far away from bat-

tery as DC cables permit.

4.2 

Never place charger directly above 

battery being charged; gases from 

battery will corrode and damage 

charger.

4.3 

Never allow battery acid to drip on 

charger when reading electrolyte 

specific gravity or filling battery.

4.4 

Do not operate charger in a closed-in 

area or restrict ventilation in any way.

4.5 

Do not set a battery on top of charger.

5. DC CONNECTION PRECAUTIONS

5.1 

Connect and disconnect DC output 

clips only after setting any charger 

switches to “off” position and remov-

ing AC cord from electric outlet. Never 

allow clips to touch each other.

5.2 

Attach clips to battery and chassis, 

as indicated in sections 6 and 7. 

Содержание 260-9510

Страница 1: ...To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference 260 9510 0099002172 00 2 Bank Automatic Battery Charger Maintainer ...

Страница 2: ...c Connection Precautions Page 6 Follow These Steps When Battery is Installed in Vehicle Page 6 Follow These Steps When Battery is Outside Vehicle Page 7 Grounding and AC Power Cord Connections Page 7 Assembly Instructions Page 8 Control Panel Page 8 Operating Instructions Page 9 Maintenance and Care Page 11 Error Codes Page 11 Troubleshooting Page 12 Specifications Page 12 Warranty Page 13 ...

Страница 3: ...cteristic of current Class II construction Double insulated construction Read the operator s manual To reduce the risk of injury read and understand the operator s manual Wear safety glasses Operation of the charger can result in damage to unprotected eyes Warning symbol Alerts user to warning message Electric shock symbol Connect only to properly grounded outlets Replace defective cords or wire i...

Страница 4: ...esult in electric shock fire and or serious personal injury SYMBOL MEANING SAFETY ALERT SYMBOL Indicates DANGER WARNING or CAUTION May be used in conjunction with other symbols or pictographs Failure to obey this safety warning WILL result in death or serious injury to yourself or to others Always follow the safety precautions to reduce the risk of fire electric shock and personal injury Failure t...

Страница 5: ...of electric shock unplug charger from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk 1 11 RISK OF EXPLOSIVE GASES a WORKINGINVICINITYOFALEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLO SIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOL LOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To ...

Страница 6: ...hes level specified by battery manufacturer Do not overfill For a battery without removable cell caps such as valve regulated lead acid batteries carefully follow manu facturer s recharging instructions 3 5 Study all battery manufacturer s spe cific precautions while charging and recommended rates of charge 3 6 Determine voltage of battery by referring to car owner s manual and make sure that outp...

Страница 7: ... RED clip to vehicle chassis or engine block away from battery Do not connect clip to carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block 6 7 When disconnecting charger turn switches to off disconnect AC cord remove clip from vehicle chassis and then remove clip from battery terminal 6 8 See Operating Instructions for length of charge in...

Страница 8: ...cord is not recommended If you must use an extension cord follow these guide lines Pins on plug of extension cord must be the same number size and shape as those of plug on charger Ensure that the extension cord is properly wired and in good electri cal condition Wire size must be large enough for the AC ampere rating of charger as specified Length of cord feet 25 50 100 150 AWG size of cord 18 18...

Страница 9: ... charger to a live grounded 120V AC outlet 5 The green Power LED will light 6 When charging is complete discon nect the charger from the AC power disconnect the negative clamp and finally the positive clamp 7 A marine boat battery must be removed and charged on shore USING THE QUICK CONNECT CABLE CONNECTORS Connect either of the two 2 output cable leads to the charger Make sure to place the charge...

Страница 10: ...d by delivering a small current when necessary If the charger has to pro vide its maximum maintain current for a continuous 12 hour period it will go into abort mode see Bad Battery section This is usually caused by a drain on the battery or the battery could be bad Make sure there are no loads on the battery If there are remove them If there are none have the battery checked or replaced MAINTAINI...

Страница 11: ...is below 14 2V for a 12V battery or 7 1V for a 6V battery The battery s initial voltage is below 12 2V for a 12V battery or 6 1V for a 6V battery and the total input is less than 1 5 Ah The battery voltage drops to below 12 2V for a 12V battery or 6 1V for a 6V battery in Maintain Mode The battery may be defective Make sure there are no loads on the battery If there are remove them If there are no...

Страница 12: ...FICATIONS Input Voltage 120V AC 60Hz 1A Output Voltage 6V or 12V with Auto Voltage Detection Output Current Rating 4A 15 REPLACEMENT PARTS Ring connectors quick connect 94030008 Battery clamps quick connect 3899002636Z ...

Страница 13: ...ise This warranty 1 excludes expendable parts including but not limited to blades brushes belts bits light bulbs and or batteries 2 shall be void if this product is used for commercial and or rental purposes and 3 does not cover any losses injuries to persons property or costs This warranty does give you specific legal rights and you may have other rights which vary from state to state Be careful ...

Страница 14: ...Page 14 NOTES ...

Страница 15: ...Page 15 NOTES ...

Страница 16: ... 2020 Menard Inc Eau Claire WI 54703 03 2020 ...

Отзывы: