17
TM
LP Tank
WARNING:
FILLING THE LP GAS CYLINDER
•
Allow only qualified LP gas dealers to properly fill or repair your LP cylinder.
•
DO NOT allow the cylinder to be filled beyond 80% capacity. Over-filled tanks can create a
dangerous condition. Over-filled tanks can build up pressure and cause the relief valve to expel
propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or
flame an explosion causing severe burns, bodily harm, or death could occur.
•
Always use a safety cap when the grill is not connected to a cylinder.
•
If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1
valve and an over-fill prevention device (OPD).
Cylinder Valve / Knob
External Male Threads
Regulator Assembly
Coupling Nut
CONNECTION PROCEDURES
1. Make sure the cylinder valve is closed (turn valve clockwise until tight).
2. Check the cylinder valve to ensure it has the proper external male threads.
3. Make sure all burner valves are turned OFF.
4. Inspect valve connections, port, and regulator assembly. Look for any
damage or debris. Remove any debris. Inspect the hose for damage. Never
attempt to use damaged or obstructed equipment. Contact your local LP
gas dealer for repair.
5. When connecting the regulator assembly to the valve, hand tighten the
quick coupling nut clockwise to a complete stop. Do not use a wrench to
tighten. Use of a wrench may damage the quick coupling nut and result in
a hazardous condition.
6. Open the cylinder valve fully (counterclockwise). Use a soapy water
solution to check all connections for leaks (a Leak Test) before
attempting to light the appliance (see P.18). If a leak is found, turn
the cylinder valve off and do not use the appliance until your LP gas dealer
can make repairs.
TO DISCONNECT THE LP CYLINDER:
1. Turn the burner valve off.
2. Turn the cylinder valve off fully (turn clockwise to stop).
3. Detach the regulator assembly from the cylinder valve by turning the quick coupling nut counterclockwise.
CAUTION:
•
When installing LP cylinders, the pressure regulator and hose supplied by the manufacturer MUST
be used with the appropriate cylinder. Replacement regulators and hoses need to be specified by
the manufacturer of this appliance.
•
Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the
type of dust cap on the cylinder valve outlet that is provided with the cylinder. Other types of caps
or plugs may result in leakage of propane.