background image

 

 

CONDENSATE EVAPORATOR 
 

The 

MPM/QMPM 

is designed to operate in an environment of 75

°

 ambient and 55% relative humidity.  When 

the conditions are applicable for condensation such as high temperature and high humidity, a large capacity 
condensate evaporator has been installed in the 

MPM/QMPM 

to ensure proper evaporation.  

 

POWER TOGGLE SWITCH

 

 
The toggle switch turns the power ON or OFF and is accessible through a slot at the back of the 

MPM/QMPM-

36 

and 

MPM/QMPM-48 

cabinet.   

 

 

 

 

NOTICE TO STORE OWNERS / MANAGERS

  

 

Moisture or liquid around or under the cabinet is a potential slip/fall hazard for persons walking by or 
working in the general area of the cabinet.  Any cabinet malfunction or housekeeping problem that 
creates a slip/fall hazard around or under the cabinet should be corrected immediately. 

 
If moisture or liquid is observed around or under a Master-Bilt cabinet, an immediate investigation should be 
made by qualified personnel to determine the source of the moisture or liquid.  The investigation made should 
determine if the cabinet is malfunctioning or if there is a drain pipe leaking. 
 

ELECTRICAL 
 

 
WARNING 
 

Before servicing electrical components in the case make sure all power to case is off.  Always use a 
qualified technician. 

 

STARTING PROCEDURE 
 

1. 

Start compressor and allow to run at least 6 hours before placing product into the 

MPM/QMPM

 
DURING THIS TESTING PERIOD YOU SHOULD: 
 
1. 

Check the temperature holding range against the the control setting. 

 
2. 

Check the defrost control system to see that all ice is removed from the coil during each defrost cycle. 

 
3. Check 

pressures. 

 

FINAL CHECK LIST 

 
A. 

Check setting of defrost timer: 

1. Verify setting of four 34 minutes defrost 
per 24 hours.   

 

 

B. 

Check operating pressures. 

 
C. 

Check electrical requirements of unit to 
supply voltage. 

 
D. 

Set temperature control for desired 
temperature range. 

 
E. 

Check system for proper defrost operation. 

 
F. 

Check condensing unit for vibrating or 
rubbing tubing.  Dampen and clamp as 
required. 

 
G. 

All valves should be completeley open 
counter-clockwise. 

 
H. 

Check packing nuts on all service valves. 

 
I. 

Replace all service valve caps and latch 
unit covers

 

 

Содержание MPM-36

Страница 1: ...1 Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 071 90000 Rev 03 06 08 ...

Страница 2: ...2 ...

Страница 3: ...or ShippingDamage 6 INSTALLATION INSTRUCTIONS 6 General Instructions 6 Thermometer Installation 6 Condensate Evaporator 8 Power Toggle Switch 8 Electrical 8 STARTING PROCEDURE 8 FINAL CHECK LIST 8 LOADING 9 CLEANING 9 SERVICE INSTRUCTIONS Trouble Shooting Guide 9 MASTER BILT PART NUMBERS 9 ACCESSORIES LIST 10 SALE AND DISPOSAL 11 WIRING DIAGRAMS 12 ...

Страница 4: ...case air flow and will result in poor performance Do not open windows or doors that will affect the case air flow The maximum air velocity near the case air return is 50 FPM If this case is to be located against a wall there should be at least a 6 space between the wall and the back of the case The cabinet also requires a clearance of 10 at the top This space will allow for the circulation of air ...

Страница 5: ... uses or services your cabinet is thoroughly familiar with all safety information and procedures Important safety information is presented in this section and throughout this section and throughout the manual The following signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you igno...

Страница 6: ...ipping crates or cartons or if a shortage is found note this on the bill of lading all copies prior to signing If damage is discovered when the cabinet is uncrated immediately call the delivering truck line and follow up the call with a written report indicating concealed damage to your shipment Ask for an immediate inspection of your concealed damage item Crating material must be retained to show...

Страница 7: ...power to the lighting circuit is turned off INSTALLATION INSTRUCTIONS To comply with N S F requirements this cabinet must be mounted on casters or the base must be sealed to the floor with NSF listed silicone sealant Optional casters screw into the holes from which the shipping bolts were removed Minimum clearance as follows 10 air space at top 6 at the rear and 0 air space at each side required f...

Страница 8: ...f the moisture or liquid The investigation made should determine if the cabinet is malfunctioning or if there is a drain pipe leaking ELECTRICAL WARNING Before servicing electrical components in the case make sure all power to case is off Always use a qualified technician STARTING PROCEDURE 1 Start compressor and allow to run at least 6 hours before placing product into the MPM QMPM DURING THIS TE...

Страница 9: ...ild detergent and water periodically SERVICE INSTRUCTIONS Trouble Shooting Guide 1 High head pressure and high back pressure A Condenser coil clogged or restricted B Condenser fan motor defective 2 Low back pressure and low head pressure A Restriction in system B Refrigerant undercharged C Leak in system 3 Pressures normal cabinet warm A Coil blocked with frost or ice see 4 B Control set too warm ...

Страница 10: ...RIPTION SHIP WT LB KG BUMPER KITS A071 00100 White bumper for QMPM 36 QMVM 36 and QMVM 36L 5 2 A071 00200 Red bumper for QMPM 36 QMVM 36 and QMVM 36L 5 2 A071 00300 Green bumper for QMPM 36 QMVM 36 and QMVM 36L 5 2 A071 00400 Blue bumper for QMPM 36 QMVM 36 and QMVM 36L 5 2 A071 00500 Brown bumper for QMPM 36 QMVM 36 and QMVM 36L 5 2 A071 00600 Black bumper for QMPM 36 QMVM 36 and QMVM 36L 5 2 A07...

Страница 11: ...CURTAIN KIT BLACK MUST BE FACTORY INSTALLED A071AB1131 For QMPM MPM 36 10 5 A072AB1131 For QMPM MPM 48 10 5 A073AB1131 For QMPM MPM 72 10 5 LIGHT KIT WHITE MUST BE FACTORY INSTALLED A071A11151 For QMPM MPM 36 15 7 A072A11151 For QMPM MPM 48 15 7 A073A11151 For QMPM MPM 72 15 7 LIGHT KIT BLACK MUST BE FACTORY INSTALLED A071AB1151 For QMPM MPM 36 15 7 A072AB1151 For QMPM MPM 48 15 7 A073AB1151 For Q...

Страница 12: ...aster Bilt at 800 684 8988 The customer service department at Master Bilt should be contacted at the time of sale or disposal of your cabinet so records may be kept of its new location If you sell or give away your Master Bilt cabinet and you evacuate the refrigerant charge before shipment Master Bilt recommends that the refrigerant charge be properly recovered in complience with section 608 of th...

Страница 13: ...12 ...

Страница 14: ...13 ...

Страница 15: ...14 ...

Страница 16: ...15 ...

Отзывы: