MASTER-BILT ELECTRONIC REFRIGERATION CONTROL
Display Lay-out
OPERATION
Compressor
When power is first turned on the controller will go through the start-up. After the start-up delay the
compressor comes on. The LED indicator stays on while compressor relay is energized. Display will show actual box
temperature. Picture above is the display layout. The compressor will be cycled off when the actual box temperature
reaches its set point. The COMP indicator will be off.
Fan
The fans will run constantly except when a defrost is initiated, or when the evaporator temp is above the 30
o
F.
When in defrost mode the fan is off until the end of the defrost and the 2 minute drip time has passed. There is 2
minutes delay after a defrost before the fan comes on. If the Evaporator temperature is 35
o
F or below the controller
will override the fan delay. FAN LED indicator is on while FAN relay is energized.
Defrost
The control uses time defrost with 4 defrost per day. The defrost scheme can be re-set the for special
applications. During defrost the display will show dEF and the defrost LED indicator on. The control begins timing the
defrost when power is turned on. Four defrost per day means it will occur every 6 hours. To have defrost occur at
8am, 2pm, 8pm, and 2am then power up at one of these four times.
MANUAL DEFROST
Defrosting my also be induced manually by keeping the defrost button for 3 seconds. Once defrost has started, the
defrost will go through a defrost and drip time pull down cycle.