7
MECHANICAL
Remove front grille and check refrigeration lines to see that they are free (not touching each other or compressor).
Spin condenser fan blade to see that it is free.
The compressor is hermetic so it is internally spring mounted and ready to run.
ELECTRICAL
WARNING
Before servicing electrical components in the case or the doors or door frames make sure all power to case is
off. Always use a qualified technician.
Check voltage and amps drawn on (Page 12-13) to determine proper line and fuse or circuit breaker size. Check power
supply for low voltage. If voltage reads “115” with no load, and it drops below “100” when the compressor tries to start,
it is an indication of too small supply wiring or too long to run.
It is recommended that a separate circuit be run for each ice merchandiser to prevent another appliance from blowing
the fuse or breaker, causing loss of product.