••••  www.master-bilt.com  •  Pg. 6 •••• 

 

 

PRODUCT LOADING 

 

The BGR series of units are not intended to be a pull down refrigerator and as such the product must be 
loaded at their intended merchandising temperature. 

 

Before loading products, allow the equipment to operate empty for at least two 
hours. 

 

When loading products: 
-

 

Do not block the lower ventilation grille with the packages about to be loaded. 

-

 

Do not over hang the shelf. 

-

 

Do not press the product against the rear wall 

-

 

Never exceed the shelf weight limits 

 
 
 
 
 
 
 
 
 
 

UNIT OPERATION AND COMPONENTS 

 

ELECTRONIC TEMPERATURE CONTROL: 

 

The unit is provided with an electronic temperature control that controls the operation of the unit based 
on the temperature of the air discharging from the evaporator at the back of the unit. 

 

In order to achieve the desired product temperature, the electronic control is factory adjusted to hold 
product at 35º – 38ºF. 

 

When  you  plug  the  unit  in,  the  control  display  will 
illuminate.  However,  there  is  a  start-up  delay  of  2 
minutes  before  the  compressor(s)  are  energized.  This 
delay  avoids  the  possibility  that  during  a  power  failure 
the  compressors  are  forced  to  restart  before  the 
refrigerant pressures are equalized. 

 

The  control  has  been  factory-adjusted  with  a  defrosting 
cycle  that  is  scheduled  to  ensure  that  the  evaporator 
performs without any ice build-up. 

 

None of the factory-programmed electronic control parameters can be modified unless an access code is 
entered (contact Master-Bilt technical service for this code). 

Содержание BGR15

Страница 1: ...North New Albany MS 38652 800 647 1284 Fax 866 882 7629 INSTALLATION AND OPERATION MANUAL BGR15 Congratulations You have just purchased the finest commercial refrigeration available 6 16 Rev A 57 025...

Страница 2: ...Master Bilt cooler when installed correctly and properly maintained will give you many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL W...

Страница 3: ...pt in storage it is suggested to keep it in its original packing In case you need your equipment to be inactive for a long period of time after being used verify that it has been unplugged After clean...

Страница 4: ...of the refrigerating system it is very important to leave at least 10 cm 4 of free space both at the sides and back to allow proper air circulation The location of the cooler must be kept away from s...

Страница 5: ...heck that the electrical data on the data plate match your electrical output IMPORTANT NOTICE PLUG THE EQUIPMENT INDEPENDENTLY TO A LOAD CENTER WITH AN APPROPRIATE CIRCUIT BREAKER ACCORDING TO THE NAM...

Страница 6: ...eration of the unit based on the temperature of the air discharging from the evaporator at the back of the unit In order to achieve the desired product temperature the electronic control is factory ad...

Страница 7: ...ATION EVAPORATOR TRAY When the equipment operates condensed water from the environment is collected on the evaporator During each off cycle the water drains to the evaporator tray located at the botto...

Страница 8: ...unit Do not allow the electronic control to be adjusted by customers or unqualified personnel For any adjustment you must contact your distributor Verify that the hot air stream from the condenser tow...

Страница 9: ...rts CLEANING THE CONDENSER COIL IMPORTANT WARRANTY INFORMATION Condensers accumulate dirt and require regular cleaning Dirty condensers result in compressor failure product loss and lost sales which a...

Страница 10: ...t immediately contact your distributor specifying the kind of problem and clearly indicating the equipment model and serial number If replacing parts is required do it through your distributor WARNING...

Отзывы: